beautypg.com

Fast & Fluid Galileo Automatic Mixer User Manual

Page 23

background image

FAST & FLUID MANAGEMENT
A Unit of Idex Corporation

Galileo

23

8. INSTALLATION CONDITIONS


Before installation please make sure of the following:
Place the Galileo Mixer on a firm and leveled floor

 220-240 VOLTAGE: Provide a clean, grounded outlet of 220 / 240 Volt (or otherwise specified following local

situations), which has a differential (MINIMUM 30mA), a magnetothermic protection of 16 Amp.

 115 VOLTAGE: Provide a clean, grounded outlet of 115 Volt (or otherwise specified following local situations), which

has a differential (MINIMUM 30mA), a magnetothermic protection of 25 Amp. and a ground net following the rules.

Environmental conditions should be within the following limits:

Ambient air temperature

:

10 to 40

C

Relative humidity

:

30 to 90 %

During the installation it is advisable to use protective gloves to avoid hand injuries

This mixer must not be installed in an explosion proof classified working area

In case an extension is needed, please make sure it is correctly dimensioned,

according to the electrical absorption of the mixer

One mixer only (therefore no other machinary) is to be connected to a single

magnetothermic switch

9. GALILEO KEYBOARD


A : Key “START” ( 35kg cans )

B : Key “START” ( 7kg cans )

C : Key “STOP”

D : Key (unclamps plates)

E : Key (clamps plates)

F : Key

G : Key

H : Display

I : Emergency push button

+

+