Heat pump heating performance continued, System design – Bryant TWO-SPEED PURON PLUS ELECTRIC HEAT PUMP 698B User Manual
Page 41

—41—
HEAT PUMP HEATING PERFORMANCE continued
* The Btuh heating capacity values shown are net “integrated” values from which the defrost effect has been subtracted. The Btuh heating from supplement
heaters should be added to those values to obtain total system capacity.
† The kW values include the compressor, outdoor fan motor, and indoor blower motor. The kW from supplement heaters should be added to these values to
obtain total system kilowatts.
EDB—Entering Dry Bulb
System Design
1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01-in. wc.
2. Minimum outdoor operating air temperature is 55°F (12.8°C).
3. Low-ambient operation accessory is not available.
4. Maximum outdoor operating air temperature is 125°F (51.7°C).
5. For reliable operation, unit should be level in all horizontal planes.
6. Maximum elevation of indoor coil above or below base of outdoor unit is; indoor coil above—50 ft, indoor coil below—150 ft.
7. For interconnecting refrigerant tube lengths greater than 50 ft, consult Application Guideline and Service Manual—Air Conditioners and Heat
Pumps Using Puron® Refrigerant.
8. If any refrigerant tubing is buried, provide a minimum 6-in. vertical rise to the valve connections at the unit. Refrigerant tubing lengths up to 36-in.
may be buried without further considerations. Do not bury lines over 36 in.
9. Use only copper wire for electric connection at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided.
10. Must be installed with factory-supplied hard shutoff, balanced port TXV (field installed).
11. Do not apply capillary tube indoor coils to these units.
12. Factory-supplied filter drier must be installed.
INDOOR
AIR
OUTDOOR COIL ENTERING AIR TEMPERATURES °F
17
27
37
47
57
67
EDB
CFM
Capacity
MBtuh†
Total
Pwr
Capacity
MBtuh†
Total
Pwr
Capacity
MBtuh†
Total
Pwr
Capacity
MBtuh†
Total
Pwr
Capacity
MBtuh†
Total
Pwr
Capacity
MBtuh†
Total
Pwr
Total
Int*
KW†
Total
Int*
KW†
Total
Int*
KW†
Total
Int*
KW†
Total
Int*
KW†
Total
Int*
KW†
698BNX060000 Outdoor Section With FV4ANB006 Indoor Section - Low Speed
65
1050
13.32
12.15
1.65
17.76
15.78
1.76
22.45
20.43
1.88
27.25
27.25
2.00
32.54
32.54
2.13
38.87
38.87
2.25
1350
13.89
12.66
1.67
18.53
16.46
1.78
23.38
21.28
1.89
28.36
28.36
1.99
34.36
34.36
2.08
37.51
37.51
2.14
1650
14.30
13.04
1.70
19.13
16.99
1.80
23.98
21.82
1.90
29.23
29.23
2.00
34.58
34.58
2.07
35.47
35.47
2.08
1950
14.90
13.59
1.73
19.49
17.31
1.82
24.51
22.31
1.92
29.73
29.73
2.02
33.27
33.27
2.05
33.44
33.44
2.05
2250
15.19
13.85
1.76
19.89
17.67
1.86
24.83
22.60
1.95
30.42
30.42
2.02
32.03
32.03
2.04
32.38
32.38
2.05
70
1050
12.49
11.39
1.68
16.78
14.90
1.80
21.42
19.49
1.93
26.22
26.22
2.06
31.40
31.40
2.19
37.53
37.53
2.31
1350
13.08
11.92
1.70
17.50
15.55
1.82
22.35
20.34
1.93
27.32
27.32
2.05
32.86
32.86
2.16
37.50
37.50
2.23
1650
13.50
12.31
1.73
18.02
16.00
1.84
23.00
20.93
1.95
28.05
28.05
2.05
34.03
34.03
2.14
35.81
35.81
2.17
1950
13.82
12.60
1.76
18.43
16.37
1.87
23.46
21.35
1.97
28.60
28.60
2.07
33.56
33.56
2.13
34.12
34.12
2.14
2250
14.10
12.85
1.80
18.75
16.65
1.90
23.86
21.71
2.00
29.09
29.09
2.10
32.69
32.69
2.13
33.28
33.28
2.14
75
1050
11.43
10.43
1.70
15.70
13.95
1.84
20.36
18.53
1.97
25.18
25.18
2.11
30.24
30.24
2.24
36.23
36.23
2.39
1350
12.02
10.96
1.73
16.46
14.62
1.85
21.28
19.36
1.98
26.27
26.27
2.10
31.59
31.59
2.22
37.75
37.75
2.33
1650
11.37
10.37
1.76
16.97
15.07
1.88
21.93
19.96
1.99
26.98
26.98
2.11
32.80
32.80
2.21
36.11
36.11
2.26
1950
12.73
11.61
1.79
17.36
15.42
1.91
22.40
20.39
2.02
27.52
27.52
2.13
33.36
33.36
2.22
34.63
34.63
2.23
2250
13.00
11.85
1.83
17.68
15.70
1.94
22.78
20.73
2.05
27.95
27.95
2.15
33.14
33.14
2.22
33.78
33.78
2.23
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section
Size
Cooling
Indoor
Section
Size
Cooling
Capacity
Power
Capacity
Power
CC5A/CD5AA
060
1.02
1.20
CK3BA
060
0.98
1.03
CC5A/CD5AB
060
1.02
1.20
CK5A/CK5BA
060
0.98
1.03
CC5A/CD5AW
060
1.04
1.19
CK5A/CK5BN
060
0.99
1.02
CE3AA
060
1.04
1.18
CK5A/CK5BT
060
0.98
1.03
CK3BA
060
1.04
1.18
CK5A/CK5BX
060
1.00
1.02
CK5A/CK5BA
060
1.04
1.18
COILS + 355MAV060100 VARIABLE SPEED FURNACE
CK5A/CK5BN
060
1.05
1.17
CC5A/CD5AA
060
0.98
1.06
CK5A/CK5BT
060
1.04
1.18
CC5A/CD5AB
060
0.98
1.06
CK5A/CK5BX
060
1.05
1.17
CC5A/CD5AW
060
1.00
1.04
FK4CNB
006
1.00
1.00
CE3AA
060
1.00
1.05
FV4ANB
006
1.00
1.00
CK3BA
060
1.00
1.05
COILS + 333(B,J)AV060100 VARIABLE SPEED FURNACE
CK5A/CK5BA
060
1.00
1.05
CC5A/CD5AA
060
0.97
1.04
CK5A/CK5BN
060
1.02
1.06
CC5A/CD5AB
060
0.97
1.04
CK5A/CK5BT
060
1.00
1.05
CC5A/CD5AW
060
0.98
1.01
CK5A/CK5BX
060
1.01
1.04
CE3AA
060
0.98
1.02
COILS + 355MAV060120 VARIABLE SPEED FURNACE
CK3BA
060
0.98
1.03
CC5A/CD5AA
060
1.01
1.07
CK5A/CK5BA
060
0.98
1.03
CC5A/CD5AB
060
1.01
1.07
CK5A/CK5BN
060
0.99
1.02
CC5A/CD5AW
060
1.01
1.06
CK5A/CK5BT
060
0.98
1.03
CE3AA
060
1.00
1.05
CK5A/CK5BX
060
0.99
1.01
CK3BA
060
1.00
1.06
COILS + 333(B,J)AV060120 VARIABLE SPEED FURNACE
CK5A/CK5BA
060
1.00
1.06
CC5A/CD5AA
060
0.98
1.03
CK5A/CK5BN
060
1.01
1.04
CC5A/CD5AB
060
0.98
1.03
CK5A/CK5BT
060
1.00
1.06
CC5A/CD5AW
060
0.98
1.03
CK5A/CK5BX
060
1.01
1.04
CE3AA
060
0.98
1.03
—
—
—