Heat pump heating performance continued – Bryant TWO-SPEED PURON PLUS ELECTRIC HEAT PUMP 698B User Manual
Page 29
—29—
HEAT PUMP HEATING PERFORMANCE continued
See notes on page 41.
INDOOR
AIR
OUTDOOR COIL ENTERING AIR TEMPERATURES °F
17
27
37
47
57
67
EDB
CFM
Capacity
MBtuh†
Total
Pwr
Capacity
MBtuh†
Total
Pwr
Capacity
MBtuh†
Total
Pwr
Capacity
MBtuh†
Total
Pwr
Capacity
MBtuh†
Total
Pwr
Capacity
MBtuh†
Total
Pwr
Total
Int*
KW†
Total
Int*
KW†
Total
Int*
KW†
Total
Int*
KW†
Total
Int*
KW†
Total
Int*
KW†
698BNX024000 Outdoor Section With FV4ANF002 Indoor Section - Low Speed
65
400
4.91
4.47
0.73
6.78
6.02
0.79
8.78
7.99
0.85
10.88
10.88
0.90
13.08
13.08
0.95
15.46
15.46
1.00
500
5.15
4.70
0.74
7.09
6.30
0.79
9.19
8.36
0.84
11.35
11.35
0.88
13.68
13.68
0.91
16.19
16.19
0.95
600
5.34
4.87
0.74
7.32
6.51
0.79
9.47
8.62
0.83
11.68
11.68
0.86
14.05
14.05
0.89
16.63
16.63
0.92
700
5.48
4.99
0.74
7.52
6.68
0.79
9.69
8.82
0.82
11.92
11.92
0.85
14.32
14.32
0.88
16.92
16.92
0.90
800
5.58
5.09
0.75
7.65
6.80
0.79
9.85
8.96
0.82
12.11
12.11
0.85
14.50
14.50
0.87
17.10
17.10
0.89
70
400
4.39
4.00
0.74
6.28
5.58
0.80
8.29
7.54
0.86
10.41
10.41
0.92
12.59
12.59
0.98
14.96
14.96
1.04
500
4.63
4.22
0.74
6.61
5.87
0.80
8.70
7.91
0.86
10.88
10.88
0.90
13.19
13.19
0.95
15.70
15.70
1.00
600
4.80
4.38
0.75
6.83
6.07
0.80
8.97
8.16
0.85
11.21
11.21
0.89
13.59
13.59
0.93
16.15
16.15
0.96
700
4.93
4.50
0.75
6.98
6.20
0.80
9.18
8.36
0.85
11.45
11.45
0.88
13.85
13.85
0.91
16.45
16.45
0.95
800
4.98
4.54
0.76
7.14
6.34
0.81
9.35
8.51
0.85
11.63
11.63
0.88
14.05
14.05
0.91
16.63
16.63
0.94
75
400
3.82
3.49
0.75
5.77
5.12
0.81
7.79
7.09
0.88
9.94
9.94
0.95
12.13
12.13
1.01
14.47
14.47
1.07
500
4.00
3.65
0.75
6.07
5.39
0.81
8.18
7.44
0.87
10.41
10.41
0.93
12.68
12.68
0.98
15.16
15.16
1.03
600
4.19
3.82
0.76
6.30
5.59
0.82
8.46
7.70
0.87
10.74
10.74
0.92
13.08
13.08
0.96
15.53
15.53
1.00
700
4.36
3.98
0.76
6.46
5.74
0.82
8.67
7.89
0.87
10.97
10.97
0.92
13.36
13.36
0.95
15.96
15.96
0.99
800
4.46
4.07
0.76
6.59
5.86
0.82
8.83
8.04
0.87
11.15
11.15
0.91
13.57
13.57
0.94
16.17
16.17
0.98
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section
Size
Cooling
Indoor
Section
Size
Cooling
Capacity
Power
Capacity
Power
CC5A/CD5AA
024
1.02
1.17
FV4ANF
002
1.00
1.00
030
1.02
1.17
003
1.00
1.00
036
1.04
1.16
COILS + 333(B,J)AV036060 VARIABLE SPEED FURNACE
CC5A/CD5AB
024
1.02
1.17
CC5A/CD5AA
024
1.02
1.06
030
1.02
1.17
030
1.02
1.04
036
1.04
1.16
036
1.02
1.01
CC5A/CD5AW
024
1.02
1.17
CC5A/CD5AB
024
1.02
1.06
030
1.02
1.17
030
1.02
1.04
036
1.04
1.16
036
1.02
1.01
CE3AA
024
1.02
1.17
CC5A/CD5AW
024
1.02
1.04
030
1.04
1.17
030
1.02
1.04
036
1.02
1.15
036
1.02
1.01
CF5AA
024
1.02
1.16
CE3AA
024
1.02
1.04
036
1.04
1.16
030
1.02
1.02
CK3BA
024
1.04
1.16
036
1.02
1.02
030
1.04
1.16
CK3BA
024
1.02
1.01
036
1.02
1.13
030
1.02
1.01
CK5A/CK5BA
024
1.04
1.16
036
1.04
1.00
030
1.04
1.16
CK5A/CK5BA
024
1.04
1.01
036
1.02
1.13
030
1.04
1.01
CK5A/CK5BN
036
1.02
1.13
036
1.04
1.00
CK5A/CK5BT
036
1.02
1.13
CK5A/CK5BN
036
1.04
1.01
CK5A/CK5BW
024
1.04
1.16
CK5A/CK5BT
036
1.04
1.00
030
1.04
1.16
CK5A/CK5BW
024
1.04
1.01
036
1.02
1.13
030
1.04
1.00
FK4CNF
001
1.00
1.01
—
—
—
002
1.00
1.00
003
1.00
1.00