Heat pump heating performance continued – Bryant TWO-SPEED PURON PLUS ELECTRIC HEAT PUMP 698B User Manual
Page 34
—34—
HEAT PUMP HEATING PERFORMANCE continued
See notes on page 41.
INDOOR
AIR
OUTDOOR COIL ENTERING AIR TEMPERATURES °F
17
27
37
47
57
67
EDB
CFM
Capacity
MBtuh†
Total
Pwr
Capacity
MBtuh†
Total
Pwr
Capacity
MBtuh†
Total
Pwr
Capacity
MBtuh†
Total
Pwr
Capacity
MBtuh†
Total
Pwr
Capacity
MBtuh†
Total
Pwr
Total
Int*
KW†
Total
Int*
KW†
Total
Int*
KW†
Total
Int*
KW†
Total
Int*
KW†
Total
Int*
KW†
698BNX036000 Outdoor Section With FV4ANF003 Indoor Section - Low Speed continued
65
650
7.80
7.11
1.05
10.39
9.22
1.11
13.12
11.94
1.17
16.00
16.00
1.23
19.18
19.18
1.29
22.62
22.62
1.37
825
8.11
7.40
1.06
10.78
9.58
1.11
13.61
12.38
1.17
16.62
16.62
1.22
19.92
19.92
1.28
23.45
23.45
1.35
1000
8.37
7.63
1.07
11.06
9.83
1.12
13.88
12.63
1.17
16.99
16.99
1.22
20.41
20.41
1.27
23.91
23.91
1.35
1175
8.52
7.77
1.09
11.28
10.02
1.13
14.19
12.91
1.18
17.28
17.28
1.23
20.60
20.60
1.29
24.19
24.19
1.36
1350
8.68
7.92
1.10
11.45
10.17
1.14
14.36
13.06
1.19
17.49
17.49
1.24
20.78
20.78
1.30
24.36
24.36
1.36
70
650
7.20
6.56
1.07
9.75
8.66
1.13
12.50
11.37
1.19
15.37
15.37
1.25
18.50
18.50
1.32
21.89
21.89
1.40
825
7.49
6.83
1.08
10.15
9.01
1.13
13.00
11.83
1.19
15.97
15.97
1.25
19.24
19.24
1.31
22.74
22.74
1.38
1000
7.71
7.03
1.09
10.43
9.26
1.14
13.34
12.14
1.19
16.39
16.39
1.25
19.67
19.67
1.31
23.23
23.23
1.38
1175
7.89
7.19
1.10
10.64
9.45
1.15
13.58
12.36
1.20
16.65
16.65
1.26
19.96
19.96
1.32
23.52
23.52
1.38
1350
8.04
7.33
1.12
10.82
9.61
1.16
13.77
12.53
1.21
16.87
16.87
1.26
20.16
20.16
1.33
23.71
23.71
1.39
75
650
6.56
5.98
1.08
9.12
8.10
1.14
11.85
10.78
1.21
14.74
14.74
1.28
17.80
17.80
1.35
21.17
21.17
1.43
825
6.84
6.23
1.09
9.50
8.44
1.15
12.35
11.24
1.21
15.25
15.25
1.27
18.53
18.53
1.34
22.00
22.00
1.41
1000
7.05
6.42
1.10
9.77
8.67
1.16
12.69
11.54
1.22
15.71
15.71
1.27
18.98
18.98
1.34
22.50
22.50
1.41
1175
7.21
6.57
1.12
9.99
8.87
1.17
12.94
11.78
1.22
15.99
15.99
1.28
19.31
19.31
1.34
22.83
22.83
1.42
1350
7.35
6.70
1.13
10.16
9.02
1.18
13.15
11.97
1.23
16.22
16.22
1.29
19.52
19.52
1.35
23.04
23.04
1.42
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section
Size
Cooling
Indoor
Section
Size
Cooling
Capacity
Power
Capacity
Power
CD5AA
048
1.00
1.00
CE3AA
036
1.04
1.06
CD5AB
048
1.00
1.00
042
1.04
1.05
CE3AA
036
1.00
1.03
048
1.04
1.04
042
1.01
1.01
CK3BA
036
1.04
1.04
048
1.01
1.01
042
1.04
1.04
CK3BA
036
1.01
1.01
048
1.04
1.04
042
1.01
1.01
CK5A/CK5BA
042
1.05
1.04
048
1.03
1.00
048
1.05
1.04
CK5A/CK5BA
042
1.01
1.01
CK5A/CK5BT
042
1.05
1.04
048
1.03
1.00
048
1.05
1.04
CK5A/CK5BT
042
1.01
1.01
CK5A/CK5BW
036
1.04
1.04
048
1.03
1.01
048
1.05
1.03
CK5A/CK5BW
036
1.01
1.01
COILS + 355MAV042060 VARIABLE SPEED FURNACE
048
1.01
1.00
CC5A/CD5AA
036
1.04
1.06
COILS + 333(B,J)AV060120 VARIABLE SPEED FURNACE
042
1.04
1.05
CC5A/CD5AA
042
1.01
1.01
CC5A/CD5AB
036
1.04
1.06
CC5A/CD5AB
042
1.01
1.01
042
1.04
1.05
CC5A/CD5AC
048
0.99
1.01
CC5A/CD5AC
048
1.03
1.06
CC5A/CD5AW
036
1.00
1.01
CC5A/CD5AW
036
1.04
1.05
042
1.00
1.00
CD5AA
048
1.04
1.05
048
1.00
1.00
CD5AB
048
1.04
1.05
CD5AA
048
1.00
1.00
CE3AA
036
1.03
1.06
CD5AB
048
1.00
1.00
042
1.04
1.05
CE3AA
036
1.00
1.03
048
1.04
1.05
042
1.01
1.01
CK3BA
036
1.04
1.05
048
1.01
1.01
042
1.05
1.05
CK3BA
036
1.01
1.01
048
1.05
1.04
042
1.01
1.01
CK5A/CK5BA
036
1.05
1.06
048
1.01
1.00
042
1.05
1.05
CK5A/CK5BA
042
1.01
1.01
048
1.05
1.04
048
1.03
1.00
CK5A/CK5BE
042
1.05
1.05
CK5A/CK5BT
042
1.01
1.01
CK5A/CK5BN
036
1.04
1.08
048
1.03
1.00
042
1.05
1.06
CK5A/CK5BW
036
1.01
1.01
048
1.05
1.05
048
1.01
1.00
CK5A/CK5BT
036
1.05
1.06
COILS + 355MAV042040 VARIABLE SPEED FURNACE
042
1.05
1.05
CC5A/CD5AA
042
1.04
1.05
048
1.05
1.04
CC5A/CD5AB
042
1.04
1.05
CK5A/CK5BW
036
1.05
1.05
CC5A/CD5AC
048
1.03
1.05
COILS + 355MAV042080 VARIABLE SPEED FURNACE
CC5A/CD5AW
036
1.04
1.05
CC5A/CD5AA
036
1.03
1.03
042
1.03
1.05
042
1.03
1.03
048
1.04
1.04
CC5A/CD5AB
036
1.03
1.03
CD5AA
048
1.04
1.05
042
1.03
1.03
CD5AB
048
1.04
1.05
CC5A/CD5AC
048
1.03
1.04