System Commands Set
Commands
Level Description
Example
show config
E
Show switch
configuration
switch>show config
show terminal
P
Show console
information
switch#show terminal
write memory
P
Save user
configuration into
permanent memory
(flash rom)
switch#write memory
system name
[System Name]
G
Configure system
name
switch(config)#system name xxx
system location
[System Location]
G
Set switch system
location string
switch(config)#system location
xxx
system description
[System Description]
G
Set switch system
description string
switch(config)#system
description xxx
system contact
[System Contact]
G
Set switch system
contact window string
switch(config)#system contact
xxx
show system-info
E
Show system
information
switch>show system-info
ip address
[Ip-address]
[Subnet-mask]
[Gateway]
G
Configure the IP
address of switch
switch(config)#ip address
192.168.1.1 255.255.255.0
192.168.1.254
ip dhcp
G
Enable DHCP client
function of switch
switch(config)#ip dhcp
show ip
P
Show IP information of
switch
switch#show ip
no ip dhcp
G
Disable DHCP client
function of switch
switch(config)#no ip dhcp
reload
G
Halt and perform a cold
restart
switch(config)#reload
default
G
Restore to default
switch(config)#default