beautypg.com

Bryant Gas 340MAV User Manual

Page 40

background image

TABLE 9—MODEL 340MAV ORIFICE SIZE AND MANIFOLD PRESSURE FOR CORRECT INPUT

(Continued)

FOR USE WITH 040 THROUGH 120 SIZE FURNACES ONLY

(TABULATED DATA BASED ON 20,000 BTUH PER BURNER, DERATED 2% FOR EACH 1000 FT ABOVE SEA LEVEL)

ALTITUDE

RANGE

(FT)

AVG GAS

HEAT VALUE

AT ALTITUDE

(BTU/CU FT)

SPECIFIC GRAVITY OF NATURAL GAS

0.58

0.60

0.62

0.64

0.66

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

U.S.A.

Only

625

43

3.8

42

3.3

42

3.4

42

3.5

42

3.6

650

43

3.5

43

3.7

43

3.8

42

3.2

42

3.3

7001

675

44

3.8

43

3.4

43

3.5

43

3.6

43

3.7

700

44

3.5

44

3.6

44

3.8

43

3.4

43

3.5

to

725

44

3.3

44

3.4

44

3.5

44

3.6

44

3.7

750

45

3.7

45

3.8

44

3.3

44

3.4

44

3.5

8000

775

45

3.5

45

3.6

45

3.7

45

3.8

44

3.3

800

45

3.3

45

3.4

45

3.5

45

3.6

45

3.7

15%

825

45

3.1

45

3.2

45

3.3

45

3.4

45

3.5

derate

850

45

2.9

45

3.0

45

3.1

45

3.2

45

3.3

ALTITUDE

RANGE

(FT)

AVG GAS

HEAT VALUE

AT ALTITUDE

(BTU/CU FT)

SPECIFIC GRAVITY OF NATURAL GAS

0.58

0.60

0.62

0.64

0.66

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

U.S.A.

Only

600

43

3.8

42

3.3

42

3.4

42

3.5

42

3.6

8001

625

43

3.5

43

3.6

43

3.8

42

3.2

42

3.3

650

44

3.7

43

3.4

43

3.5

43

3.6

43

3.7

to

675

44

3.5

44

3.6

44

3.7

44

3.8

43

3.4

700

44

3.2

44

3.3

44

3.4

44

3.6

44

3.7

9000

725

45

3.6

45

3.8

44

3.2

44

3.3

44

3.4

750

45

3.4

45

3.5

45

3.6

45

3.8

44

3.2

17%

775

45

3.2

45

3.3

45

3.4

45

3.5

45

3.6

derate

800

45

3.0

45

3.1

45

3.2

45

3.3

45

3.4

ALTITUDE

RANGE

(FT)

AVG GAS

HEAT VALUE

AT ALTITUDE

(BTU/CU FT)

SPECIFIC GRAVITY OF NATURAL GAS

0.58

0.60

0.62

0.64

0.66

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

U.S.A.

Only

575

43

3.8

42

3.2

42

3.3

42

3.5

42

3.6

9001

600

43

3.5

43

3.6

43

3.7

42

3.2

42

3.3

625

44

3.7

44

3.8

43

3.5

43

3.6

43

3.7

to

650

44

3.4

44

3.5

44

3.7

44

3.8

43

3.4

675

45

3.8

44

3.3

44

3.4

44

3.5

44

3.6

10,000

700

45

3.6

45

3.7

45

3.8

44

3.3

44

3.4

725

45

3.3

45

3.4

45

3.6

45

3.7

45

3.8

19%

750

45

3.1

45

3.2

45

3.3

45

3.4

45

3.5

derate

775

45

2.9

45

3.0

45

3.1

45

3.2

45

3.3

*Orifice numbers shown in BOLD are factory installed.

Percents of derate are based on midpoints of U.S. altitude ranges.

—40—