background image

TABLE 9—MODEL 340MAV ORIFICE SIZE AND MANIFOLD PRESSURE FOR CORRECT INPUT

(Continued)

FOR USE WITH 040 THROUGH 120 SIZE FURNACES ONLY

(TABULATED DATA BASED ON 20,000 BTUH PER BURNER, DERATED 2% FOR EACH 1000 FT ABOVE SEA LEVEL)

ALTITUDE

RANGE

(FT)

AVG GAS

HEAT VALUE

AT ALTITUDE

(BTU/CU FT)

SPECIFIC GRAVITY OF NATURAL GAS

0.58

0.60

0.62

0.64

0.66

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

U.S.A.

Only

725

43

3.7

43

3.8

42

3.2

42

3.3

42

3.4

750

43

3.4

43

3.5

43

3.7

43

3.8

42

3.2

4001

775

44

3.7

44

3.8

43

3.4

43

3.5

43

3.7

800

44

3.5

44

3.6

44

3.7

44

3.8

43

3.4

to

825

44

3.2

44

3.4

44

3.5

44

3.6

44

3.7

850

45

3.7

45

3.8

44

3.3

44

3.4

44

3.5

5000

875

45

3.5

45

3.6

45

3.7

44

3.2

44

3.3

900

45

3.3

45

3.4

45

3.5

45

3.6

45

3.8

0%

925

45

3.1

45

3.2

45

3.3

45

3.4

45

3.6

derate

950

45

3.0

45

3.1

45

3.2

45

3.3

45

3.4

ALTITUDE

RANGE

(FT)

AVG GAS

HEAT VALUE

AT ALTITUDE

(BTU/CU FT)

SPECIFIC GRAVITY OF NATURAL GAS

0.58

0.60

0.62

0.64

0.66

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

U.S.A.

Only

700

43

3.6

43

3.7

42

3.2

42

3.3

42

3.4

725

43

3.4

43

3.5

43

3.6

43

3.7

43

3.8

750

44

3.6

44

3.7

43

3.4

43

3.5

43

3.6

775

44

3.4

44

3.5

44

3.6

44

3.7

43

3.4

5001

800

44

3.2

44

3.3

44

3.4

44

3.5

44

3.6

825

45

3.6

45

3.7

44

3.2

44

3.3

44

3.4

to

850

45

3.4

45

3.5

45

3.6

45

3.8

44

3.2

875

45

3.2

45

3.3

45

3.4

45

3.6

45

3.7

6000

900

45

3.0

45

3.1

45

3.3

45

3.4

45

3.5

925

45

2.9

45

3.0

45

3.1

45

3.2

45

3.3

950

45

2.7

45

2.8

45

2.9

45

3.0

45

3.1

11%

975

45

2.6

45

2.7

45

2.8

45

2.9

45

2.9

derate

1000

45

2.5

45

2.5

45

2.6

45

2.7

45

2.8

ALTITUDE

RANGE

(FT)

AVG GAS

HEAT VALUE

AT ALTITUDE

(BTU/CU FT)

SPECIFIC GRAVITY OF NATURAL GAS

0.58

0.60

0.62

0.64

0.66

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

U.S.A.

Only

650

42

3.2

42

3.3

42

3.4

42

3.5

42

3.6

675

43

3.6

43

3.7

43

3.8

42

3.2

42

3.3

6001

700

44

3.8

43

3.4

43

3.6

43

3.7

43

3.8

725

44

3.6

44

3.7

44

3.8

43

3.4

43

3.5

to

750

44

3.3

44

3.4

44

3.6

44

3.7

44

3.8

775

45

3.8

44

3.2

44

3.3

44

3.4

44

3.5

7000

800

45

3.5

45

3.7

45

3.8

44

3.2

44

3.3

825

45

3.3

45

3.4

45

3.6

45

3.7

45

3.8

13%

850

45

3.1

45

3.2

45

3.4

45

3.5

45

3.6

derate

875

45

3.0

45

3.1

45

3.2

45

3.3

45

3.4

*Orifice numbers shown in BOLD are factory installed.

Percents of derate are based on midpoints of U.S. altitude ranges.

—39—