beautypg.com

Physical data, Blower performance data – Bryant 313AAV/JAV User Manual

Page 5

background image

5

PHYSICAL DATA

UNIT SIZE

024045

048070

048090

060110

060135

OUTPUT CAPACITY

BTUH

(Non---weatherized ICS)

313JAV Upflow; all 313AAV

36,000

53,000

72,000

90,000

107,000

313JAV Downflow/Horizontal

34,000

51,000

69,000

86,000

102,000

INPUT BTUH

313JAV Upflow; all 313AAV

44,000

66,000

88,000

110,000

132,000

313JAV Downflow/Horizontal

42,000

63,000

84,000

105,000

126,000

AFUE%

Non---weatherized ICS

80.0

80.0

80.0

80.0

80.0

SHIPPING WEIGHT LB. (KG)

104 (47)

126 (57)

140 (64)

152 (69)

163 (74)

CERTIFIED TEMP RISE RANGE

˚_F (_C)

30---60

(17---33)

25---55

(14---31)

35---65

(19---36)

30---60

(17---33)

40---70

(22---39)

CERTIFIED EXT STATIC

PRESSURE (IN. WC)

Heating

0.10

0.12

0.15

0.20

0.20

Cooling

0.50

0.50

0.50

0.50

0.50

AIRFLOW CFM

Heating

735

1230

1345

1890

1865

Cooling

1035

1460

1665

2040

2070

LIMIT CONTROL

SPST

HEATING BLOWER CONTROL

Solid---State Time Operation

BURNERS (Monoport)

2

3

4

5

6

GAS CONNECTION SIZE

1/2---in. NPT

GAS VALVE(Redundant) Manufacturer

White---Rodgers

Minimum Inlet Pressure (in. wc)

4.5 (Natural Gas)

Maximum Inlet Pressure (in. wc)

13.6 (Natural Gas)

IGNITION DEVICE

Hot Surface

*Gas input ratings are certified for elevations to 2000 ft. (610 M)*. In USA, For elevations above 2000 ft. (610 M), reduce ratings 4 percent for each 1000 ft. (305

M) above sea level. In Canada, derate the unit 10 percent for elevations 2000 to 4500 ft. (610 --- 1372 M) above sea level. Refer to National Fuel Gas Code

NFPA 54/ANSI Z223.1---2006 Table F.1 (d) or furnace Installation Instructions.
{

Capacity in accordance with U.S. Government DOE test procedures.

}

Airflow shown is for bottom only return---air supply. For air delivery above 1800 CFM, see Air Delivery Table for other options. A filter is required for each

return---air supply. An airflow reduction of up to 7 percent may occur when using a Bryant 4---5/16 in. (110 mm) high efficiency media filter.

ICS --- Isolated Combustion System

BLOWER PERFORMANCE DATA

UNIT SIZE

024045

048070

048090

060110

060135

DIRECT---DRIVE MOTOR Hp (ECM --- 5 Speed)

1/2

3/4

3/4

1

1

MOTOR FULL LOAD AMPS

6.8

8.4

8.4

10.9

10.9

RPM (Nominal) --- SPEEDS

1050---5

1050---5

1050---5

1050---5

1050---5

BLOWER WHEEL DIAMETER x WIDTHS --- IN (MM)

10 x 6

(254 x 152)

11 x 8

(279 x 203)

10X10

(254 x 254)

11 x 11

(279 x 279)

11 x 11

(279 x 279)

313AA

V/

JA

V