beautypg.com

Bryant LOW-BOY 367AAN User Manual

Page 11

background image

1. Turn off all oil and electrical supplies upstream of furnace.

CAUTION:

If furnace has been in operation, some

surfaces may be hot. Allow time for unit to cool down.

2. Disconnect flue pipe.

3. Remove flue collar panel located in rear part of furnace.

4. Remove flue silencer from secondary heat exchanger.

5. Disconnect oil line and remove oil burner from furnace.

6. Clean primary and secondary heat exchangers with a stiff

brush and vacuum cleaner.

7. Before reassembly, heat exchanger/combustion chamber

should be inspected to determine if replacement is required.

8. After cleaning, replace flue silencer, flue collar, and oil

burner.

9. Readjust burner for proper operation.

IV.

BLOWER REMOVAL

To remove blower from furnace:

1. Turn off all oil and electrical supplies upstream of furnace.

2. Remove blower access door.

3. Remove air filters.

4. Remove blower retaining wing nuts.

5. Slide blower on rails toward rear of unit.

6. Reverse items 1 through 5 to reinstall blower. Refer to

wiring diagram (Fig. 3 or Fig. 4) of these instructions or
diagram located on inside of blower door to properly rewire
unit.

—11—