beautypg.com

Electrical hook-up – Bunn Dual TF DBC User Manual

Page 6

background image

Page 6

L1, L2, L3, are the 3 phases
V1 = Phase to phase voltage, between any 2 phases.
V2 = Phase to neutral voltage, L1 to neutral must be 120V.

SYSTEM
VOLTAGE

V1

V2

208

208 120

240

240 120

CAUTION: Do not connect L1 to a circuit operating at
more than 150 volts to ground.

200 and 230 volt ac

single phase, 60 Hz models

Note: This electrical service
consists of 2 current carrying
conductors (L1 and L2) and a
separate conductor for earth
ground.

120/208 and 120/240 volt ac

three phase, 50 Hz models

Note: This electrical service
consists of 4 current carrying
conductors (Neutral, L1, L2
and L3) and a separate con-
ductor for earth ground.

ELECTRICAL HOOK-UP

CAUTION – Improper electrical installation will damage electronic components. Damage caused by incorrect

electrical connections is not covered by warranty.

1. An electrician must provide electrical service as specifi ed.
2. Using a voltmeter, check the voltage and color coding of each conductor at the electrical source.
3. Remove the front panel beneath the sprayheads to gain access to the terminal block.
4. Feed the cord through the strain relief and connect it to the terminal block.
5. Connect the brewer to the power source and verify the voltage at the terminal block before proceeding. Re-

place the front panel.

6. If plumbing is to be hooked up later be sure the brewer is disconnected from the power source. If plumbing

has been hooked up, the brewer is ready for Initial Set-Up.

WARNING – Electrical connections must be made as specifi ed above. Failure to follow these instructions can

result in personal injury, property or equipment damage.

ELECTRICAL REQUIREMENTS (Models without power cord)

WARNING - The brewer must be disconnected from the power source until specifi ed in Initial Set-Up.

Refer to Data Plate on the Brewer, and local/national electrical codes to determine circuit requirements.

,

7()4%

'2%%.

.%542!,

,

,

'2%%.

L2 RED

200 or

230V

GREEN

L1 BLACK

GREEN

35058.1 071205