Programming the brewer (cont.) – Bunn Dual TF DBC User Manual

Page 40

background image

Page 40

SERVICE TOOLS (cont.)

PROGRAMMING THE BREWER (cont.)

9. After all switches have been tested, press and re-

lease the right hidden switch (®). This will return
to TEST SWITCHES?. Press and release switch
again to advance to TEST SERVERS?. Another
alternative is to press and release either ON/OFF
switch located on the front switch panel. This
will exit TEST SWITCHES and return to the MAIN
SCREEN.

Procedures to test coil frequency:
1. Place brew funnels into rails on both sides of

brewer.

2. Place a Soft Heat server beneath each brew fun-

nel.

3. Press and hold the upper right hidden switch

until the display reads UNITS. Release the switch.
Continue pressing and releasing the upper right
hidden switch until SERVICE TOOLS appears.

4. Pressing

NO will exit this function and advance to

the next function screen. Press YES to run tests
on various components and outputs within the
brewer.

5. The display should read TEST OUTPUTS?.
6. In

TEST OUTPUTS screen, press NO. Continue to

press and release NO until the display reads TEST
FREQUENCY?.

7. Press and release YES. The display will show the

frequency of the sensor coil circuits. This is for
diagnostic service use when troubleshooting this
circuit.

8. After the coils have been tested, press and release

either ON/OFF switch located on the front switch
panel. This will exit the TEST FREQUENCY function
and return to the MAIN SCREEN.

NOTE: If the operator wishes to test more than one

function in the SERVICE TOOLS section (outputs,
switches, servers, or coil frequency), it is not
necessary to exit the program. Use the fl ow chart
for SERVICE TOOLS to navigate to a particular
function.

FACTORY DEFAULTS

This function allows the operator to erase all of the

previously entered recipes and ad messages. Factory-
set default values will replace all previous settings.

EXIT

EXIT

REPLACE

WILL REPLACE ALL

BREW SETTINGS

ARE YOU SURE?

NO YES

FACTORY DEFAULTS

NO YES

ThermoF SoftHeat

DONE

SEL BREWER TYPE?

NO YES

P2312