To change injectors, Changing the nozzles of the burners on the cooktop – Neff T22S46N0 User Manual
Page 12
12
Converting the
cooktop from Nat.
Gas to Universal LPG
To change injectors
All work involved in installation, setting and adaptation to
a different gas type must be carried out by authorised
personnel from our Service Centre and must comply with
current regulations and the conditions laid down by the
local gas company.
Request change-over injectors from our customer service
deparment (refer injector chart below for sizes).
Before conversion the cooktop must be disconnected
from the electricity and gas valves must be turned to the
OFF position.
Changing the nozzles
of the burners on the
cooktop
- Remove the pan supports, burner covers and
diffusers.Fig. 7.
- Change the nozzles using the spanner provided by our
Service Centre (code 340847, for double and triple flame
burners code 340808), taking special care to ensure that
the nozzle does not fall when it is removed from the
burner or when fitted. Fig. 8.
Natural Gas
Universal LPG
Burner
Hourly Gas
Consumption
(MJ)
Injector
mark
Hourly Gas
Consumption
(MJ)
Injector
mark
(mm)
Auxiliary
3,60
90
3,50
50
Semi-rapid
6,50
118
6,00
67
Rapid
10,80
155
10,00
85
(60) Double
flame
12,00
160
11,00
91
(70) Double
flame (inner)
18,00
85
18,00
46
(70) Double
flame (outer)
140
71
Fig. 7