Clearances – Neff T69S86N0 User Manual
Page 9
9
Before connecting the unit, check whether the local
connection conditions (type of gas) are compatible with
the unit’s setting. Observe any special conditions
imposed by local suppliers (utilities). The specifications
of this cooktop are stated on the data label located on the
bottom of the cooktop base.
A duplicate data label is supplied for adhesion to an
accessible location near the hotplate if the data label on
the base of the hotplate cannot be accessed when the
hotplate is installed.
Clearances
A range hood fitted above the top must be installed
according to the installation instructions for the range
hood. A minimum distance of 650 mm is required for a
range hood and 750 mm for an exhaust fan.
Any adjoining wall surface situated within 200 mm from
the edge of any hob burner must be a suitable non-
combustible material for a height of 150mm for the entire
length of the hob. Any combustible construction above
the hotplate must be at least 650 mm above the top of
the burner and no construction shall be within 450 mm
above the top of the burner.
A minimum depth of 50 mm from the top of the worktop
surface must be provided for the appliance.
If the base of the hotplate can be touched, a protecting
shield must be fitted. This shield must be at least 10 mm
from the lowest part of the hotplate and must be capable
of withstanding the appliance temperatures. Minimum
thickness of benchtop is 30 mm. See Fig. 2.
Fig. 2