2remote control parameters (continued) – BEA IS40P User Manual
Page 5

2
Remote Control Parameters (Continued)
FUNCTION
AFFECTS
INFRARED OR
MICROWAVE
REMOTE
CONTROL
BUTTON
FUNCTION DESCRIPTION
SENSITIVITY
MICROWAVE
0 - 9: (7 - Default)
DETECTION
MODE
MICROWAVE
1: Bidirectional (Towards or Away from Sensors)
2: Unidirectional Approach (Towards Sensor)
3: Unidirectional Depart (Away from Sensor)
REJECTION
MODE
MICROWAVE
1: Detection of all kind of Targets
in Motion
2: Detection of all kind of Targets in Motion
+ Interference Immunity
3: Low ‘Pedestrian/Parallel traffic’ Rejection
+ Interference Immunity
4: Medium ‘Pedestrian/Parallel traffic’
Rejection + Interference Immunity
5: High ‘Pedestrian/Parallel traffic’ Rejection
+ Interference Immunity
ACTIVATION
RELAY
HOLD TIME
MICROWAVE
0: 0.5 second
1: 1.0 second
2: 2.0 seconds
3: 3.0 seconds
4: 4.0 seconds
5: 5.0 seconds
6: 6.0 seconds
7: 7.0 seconds
8: 8.0 seconds
9: 9.0 seconds
RELAY
CONFIGURATION
INFRARED
MICROWAVE
Description
Active
Passive
Detection
COM
COM
No Detection
COM
COM
NO
NC
NO
NC
NO
NC
NO
NC
Activation
Relay
Presence
Relay
1
Active
Passive
2
Passive
Active
3
Passive
Passive
4
Active
Active
OUTPUT
CONFIGURATION
INFRARED
MICROWAVE
PRESENCE RELAY
IS40
IS40P
0 - 4: ALL MODES
Activates when object is in
presence zone.
Activates when object is
in presence zone.
ACTIVATION RELAY
IS40
IS40P
0: STANDARD MODE
Activates when motion
detected.
Activates when object is
in presence zone.
1: PULSE ON ENTRY
Activates if object motion is
detected and then object enters
presence zone.
Activates when object
enters presence zone.
2: PULSE ON EXIT
Activates if object motion is
detected and then object exits
presence zone.
Activaties when object exits
presence zone.
3: PULSE ON ENTRY
FIRST / LAST LINE
(See Example to the Left)
Activates if object motion is
detected and then object enters
presence zone (first or last line).
Activates when object
enters presence zone (first
or last line).
4: PULSE ON EXIT
FIRST / LAST LINE
(See Example to the Left)
Activates if object motion is
detected and then object exits
presence zone (first or last line).
Activates when object exits
presence zone (first or last
line).
SETUP
INFRARED
MICROWAVE
Initiate Setup, press
DEFAULT
VALUES
INFRARED
MICROWAVE
To set Factory Defaults, press
DOOR EXAMPLE
LAST LINE
FIRST LINE
F1
75.5371.01 EN 20080505 (75.5370)
Page 5 of 6
6 3 0 3 6
3
6
9
12
15
18
Height = 16 ft.
S = 3
S = 9
S = 6
FT.
Sensitivity 9, 6, 3
9
0