7 remote control functions, 2microwave field tilt angle – BEA IS40P User Manual
Page 3

75.5371.01 EN 20080505 (75.5370)
Page 3 of 6
2
Microwave Field Tilt Angle
-
3.25
6.50
9.75
13.0
19.7
23.0
26.3
16.3
3.25
0
3.25
6.50
6.50
ft
ft
Mounting height: 16 ft.
Sensitivity: 9
Sensor angle: 20°
-
+
MIN
MAX
By turning the tilt
angle adjustment
screw clockwise,
the radar field
angle is reduced.
By turning the tilt
angle adjustment
screw counter
clockwise, the
radar field angle
is increased.
7 Remote Control Functions
Every programming session begins by unlocking the sensor. Thereafter a program setting may be altered by pressing the desired function key
followed by the desired value for that function. When all programming is complete press the lock key twice to retain settings. Use the following
as a guide:
Unlock
the sensor to enter into adjustment
session (if no access code has been entered)
To change the value of a parameter
(ex. Automatic Learn Time)
… to change any other parameters
(ex. Relay Configuration)
To check the value of a parameter (ex.
Automatic Learn Time)
Lock
the adjustment session and go back to
normal function
Press Unlock Key
RED LED
Flashes Slowly
Select Parameter
to Change
RED LED
Flashes Quickly
Enter New Value
RED LED
Flashes Slowly
Select Parameter
to Change
RED LED
Flashes Quickly
Enter New Value
RED LED
Flashes Slowly
Select Parameter
to Check
RED LED
Flashes Quickly
Press Question
Mark
The Number of Green Flashes Indicate
the Value of This Parameter
RED LED
Flashes Slowly
Press Lock Key Twice
OR
+ Lock Code
0-9
0-9
?