8 setup & startup, 2remote control parameters, F2 1 setup sequence – BEA IS40P User Manual
Page 4

Page 4 of 6
75.5371.01 EN 20080505 (75.5370)
2
Remote Control Parameters
FUNCTION
AFFECTS
INFRARED OR
MICROWAVE
REMOTE
CONTROL
BUTTON
FUNCTION DESCRIPTION
AUTOMATIC
LEARN TIME
INFRARED
0: 30 seconds
1: 1 minute
2: 2 minutes
3: 5 minutes
4: 10 minutes
5: 20 minutes
6: 60 minutes
9:
∞
(Infi nity)
IMMUNITY
INFRARED
1: Low (Normal)
2: Medium (Rain)
3: High (Snow)
PATTERN
INFRARED
FREQUENCY
INFRARED
1: L - L’ Pulse Frequency
2: H - H’ Pulse Frequency
TARGET SIZE
INFRARED
Defi ne the Minimum Target Size
8 Setup & Startup
6
7
8
9
DOOR
DOOR
DOOR
DOOR
DOOR
DOOR
DOOR
DOOR
DOOR
F2
1
Setup Sequence
1. Power on the sensor. Sensor automatically performs a Setup on power up and Setup is complete when Red/Green fl ashing stops.
2. If the Detection Zone (Background) permanently changes and a new Setup is required, perform a new Setup by pressing
. Red & Green LEDs will blink rapidly until setup is complete.
NOTE
: Avoid movement in the IR zone during setup.
0
0
1 x 1
1:
2 x 2
2:
3 x 3
3:
4 x 4
4:
1 x 2
5:
2 x 3
6:
3 x 2
7:
1
2
3
4
5
6
7
8
9