beautypg.com

Olympus E-620 User Manual

Page 146

background image

146

EN

Inf
o

rm

a

tion

12

„

Exposure control

Metering system

: TTL full-aperture metering system

(1) Digital ESP metering
(2) Center weighted averaging metering
(3) Spot metering (approx. 2% for the viewfinder screen)

Metering range

: EV 1 – 20 (Digital ESP metering, Center weighted average metering,

Spot metering) (At room temperature, 50 mm f2, ISO 100)

Shooting modes

: (1)

AUTO: Fully automatic

(2) P

: Program AE (Program shift can be performed)

(3) A

: Aperture priority AE

(4) S

: Shutter priority AE

(5) M

: Manual

ISO sensitivity

: 100 – 3200 (1/3, 1 EV step)

Exposure compensation

: ±5 EV (1/3, 1/2, 1 EV step)

„

White balance

Product type

: Image pickup device

Mode setting

: Auto, Preset WB (8 settings), Customized WB, One-touch WB

„

Recording

Memory

: CF card (Compatible with Type I and II)

Microdrive (Compatible with FAT 16/32)
xD-Picture Card

Recording system

: Digital recording, JPEG (in accordance with Design rule for Camera

File system (DCF)), RAW Data

Applicable standards

: Exif 2.2, Digital Print Order Format (DPOF), PRINT Image Matching III,

PictBridge

„

Playback

Playback mode

: Single-frame playback, Close-up playback, Index display, Image

rotation, Slideshow, Light box display, Calendar display

Information display

: Information display, Histogram display

„

Drive

Drive mode

: Single-frame shooting, Sequential shooting, Self-timer, Remote control

Sequential shooting

: 4 frames/sec.

Self-timer

: Operation time: 12 sec., 2 sec.

Optical remote control

: Operation time: 2 sec., 0 sec. (instantaneous shooting)

(RM-1 Remote Control [optional])

„

Flash

Synchronization

: Synchronized with the camera at 1/180 sec. or less

Flash control mode

: TTL-AUTO (TTL pre-flash mode), AUTO, MANUAL

External flash attachment

: Hot shoe

Wireless flash function

: Compatible with the Olympus wireless RC flash system

„

External connector

USB connector, VIDEO OUT connector (Multi-connector)

„

Power supply

Battery

: Li-ion Battery (BLS-1) x1

„

Dimensions/weight

Dimensions

: 130.0 mm (W) x 94.0 mm (H) x 60.0 mm (D) (5.1" x 3.7" x 2.4")

(excluding protrusions)

Weight

: Approx. 475 g (1.0 Ib.) (without battery)

„

Operating environment

Temperature

: 0 °C – 40 °C (32 °F – 104 °F) (operation)/

–20 °C – 60 °C (–4 °F – 140 °F) (storage)

Humidity

: 30 – 90% (operation)/10 – 90% (storage)

E-620_MASTER.fm Seite 146 Dienstag, 17. Februar 2009 11:04 11