Scan to FTP/SMB (Optional)
Copyright © 2007, Xerox Corporation. All rights reserved.
11
4.
Set an IP Address.
If an IP address is already set, this step is not necessary. Also, in an environment with
DHCP or BOOTP, configure the way to obtain an IP address. If the address cannot be
obtained automatically, or static configuration is preferred, configure an IP address, a
subnet mask, and a gateway address as follows.
a.
From the Tools tab, touch Connectivity and Network Setup, then touch
Protocol Settings.
b.
Select IPv4 (or other mode) Address Resolution, then select Change Settings.
c.
Select one from [DHCP], [BOOTP], [RARP], [DHCP/Autonet] or [Static], and
then select Save. If you select anything other than [Static], proceed to Step 5.
Note: When communicating by TCP/IP make sure to enable the use of a DNS (or
WINS for SMB) server. This is done using the machine's Internet Services web pages,
displayed by typing the machine's IP address into your web browser (as stated in the
TCP/IP Dynamic Addressing Topic of this guide).
d.
On the Protocol Settings screen, select TCP/IP - IP Address and then Change
Settings.
e.
Enter the IP Address using the numeric keypad.
Note: Enter the address in the format "xxx.xxx.xxx.xxx". The "xxx" should be a
numeric value in the range from 0 to 255. However, 224 - 255.xxx.xxx.xxx and
127.xxx.xxx.xxx cannot be used.
f.
Select Save.
g.
Configure TCP/IP - Subnet Mask and TCP/IP - Gateway Address using the
same process as stated above.
Note: Enter the Gateway address in the format "xxx.xxx.xxx.xxx". The "xxx" should be
a numeric value in the range from 0 to 255. However, 224 - 255.xxx.xxx.xxx and
127.xxx.xxx.xxx cannot be used.
Specify the subnet mask by a combination of the numbers 0, 128, 192, 224, 240, 248,
252, 254, and 255. However, you cannot use 0 between non-zero values. If you do not
set the gateway address, enter "0.0.0.0".
5.
Select Close until the Tools tab screen is displayed.
6.
Wait several seconds for the Auto Clear service to log you out.
7.
If you changed any settings, the Device will automatically reboot to register and enable
your new settings. After the machine is restarted, print out a Configuration Report to
confirm that the ports are enabled and TCP/IP is correctly configured.
If remote authentication has been enabled, a separate login screen appears when the Scan to
FTP/SMB feature is selected. Documents are not scanned in unless the remote authentication
server authenticates user access.
- WorkCentre 7328-7335-7345-7346 con built-in controller-15392 WorkCentre 7328-7335-7345-7346 con EFI Fiery Controller-15396 WorkCentre 7328-7335-7345-7346 con built-in controller-15114 WorkCentre 7328-7335-7345-7346 con EFI Fiery Controller-15118 WorkCentre 7328-7335-7345-7346 con EFI Fiery Controller-15757 WorkCentre 7328-7335-7345-7346 avec built-in controller-12617 WorkCentre 7328-7335-7345-7346 avec EFI Fiery Controller-11909 WorkCentre 7328-7335-7345-7346 avec built-in controller-12214 WorkCentre 7328-7335-7345-7346 avec EFI Fiery Controller-12623 WorkCentre 7328-7335-7345-7346 avec EFI Fiery Controller-12220 WorkCentre 7328-7335-7345-7346 avec built-in controller-11903 WorkCentre 7328-7335-7345-7346 mit built-in controller-9447 WorkCentre 7328-7335-7345-7346 mit EFI Fiery Controller-9751 WorkCentre 7328-7335-7345-7346 mit EFI Fiery Controller-9452 WorkCentre 7328-7335-7345-7346 mit built-in controller-9746 WorkCentre 7328-7335-7345-7346 mit EFI Fiery Controller-10140 WorkCentre 7328-7335-7345-7346 mit built-in controller-10135 WorkCentre 7328-7335-7345-7346 con built-in controller-18247 WorkCentre 7328-7335-7345-7346 con EFI Fiery Controller-17858 WorkCentre 7328-7335-7345-7346 con built-in controller-17547 WorkCentre 7328-7335-7345-7346 con EFI Fiery Controller-18252 WorkCentre 7328-7335-7345-7346 con EFI Fiery Controller-17552 WorkCentre 7328-7335-7345-7346 con built-in controller-17853