Programming

F232090

34

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

4. Press the Heat key. The display will read either

“080F” or “025C,” depending on whether
Fahrenheit or Centigrade is prompted.

Enter the desired fill temperature. Three digits
must be entered. If the desired temperature is less
than 100 degrees, the first digit must be 0.

The valid temperature range is 80–200 degrees
Fahrenheit and 25–93 degrees Centigrade. The
computer will not accept temperatures out of this
range. (The fill temperatures possible are
governed by the temperature of the available hot
water.)

5. Press the Enter key. The display will read

“M---S.” Now assign the maximum time to be
allowed for reaching the fill level in minutes and
seconds.

6. Press the Enter key, and go to the next step in the

cycle.

The computer will attempt to maintain the
temperature within a margin of plus or minus 5
degrees of the target fill temperature during such
a step.

Fill Temperature Programming

Keys Pressed

Display

Valves Operating

Hot + Low + Enter

“HL”

1 Hot Fill and 1 Hot Spray

Hot + Med + Enter

“HM”

1 Hot Fill and 1 Hot Spray

Hot + High + Enter

“HH”

1 Hot Fill and 1 Hot Spray

Warm + Warm + Low + Enter

“WL”

Both Hot and Both Cold

Warm + Hot + Low + Enter

“WL”

Both Hot and 1 Cold Fill

Warm + Cold + Low + Enter

“WL”

1 Hot Fill and Both Cold

Cold + Low + Enter

“CL”

1 Cold Fill and 1 Cold Spray

Cold + Med* + Enter

“CM”

1 Cold Fill and 1 Cold Spray

Cold + High + Enter

“CH”

1 Cold Fill and 1 Cold Spray

In addition to the standard fill temperatures, computer-controlled fill or overflow to a specific temperature is available.