Vollrath M202B Water Cooled User Manual
Page 25

Owner’s Manual #513666 Rev.1
19
M202B Model Machines
4.3 TROUBLESHOOTING TABLES
PROBLEM
POSSIBLE CAUSE
REMEDY
Custard is running
too cold or auger
blades chatter
during running.
1
Flow is not high enough.
1
Increase the fl ow. Machine needs to run for at
least a minute before you see a change in the
product.
2
Hopper is low or out of mix.
2
Add Mix
3
Flow valve is plugged.
3
Check fl ow valve.
4
The refrigeration system is set too cold
for the mix.
4
Call Stoelting service department and we can
help over the phone to adjust setting properly.
Custard is running
too soft.
1
Flow is too high.
1
Decrease the fl ow. Machine needs to run for at
least a minute before you see a change in the
product.
2
The refrigeration system for that barrel
set too warm for the mix.
2
Call Stoelting service department and we can
help over the phone to adjust setting properly.
3
Air fl ow to condenser is blocked.
3
Check for blockage and clean if necessary.
4
Water cooled machine has water shut
off.
4
Check that water is connected and turned on.
5
Refrigeration system not functioning
correctly.
5
Call Stoelting service department.
Beater motor
freezes up in the
run mode.
1
Hopper is low or out of mix.
1
Add Mix
2
Flow valve is plugged.
2
Check fl ow valve.
3
Flow valve is set too low.
3
Increase the fl ow setting.
4
Belt is loose and slipping.
4
Check the belt and tighten if necessary.
Restriction of
custard or lemon
ice in the faceplate
1
Restriction in the faceplate.
1
Use the rake to free the restriction and
increase the fl ow rate setting by about 0.5.
After a minute, repeat these steps if no results
are seen.
2
Solid obstruction in faceplate.
2
Inspect the fl ow valve for solid custard or
lemon pulp obstruction in the hopper.