5.
Set the pressures for the remaining cylinders.
NOTE
If the machine is water-cooled, the discharge pres-
sure was already set at the factory. Run custard
mix through the machine to double-check and
fi ne-tune the discharge pressure for the particular
mix being used.
The remote condenser unit has a head pressure
control set for 245 psi.
Custard mixes that use an extract fl avoring will run
differently. Try different pressure settings by adjust-
ing the AXV. Adjust the pressure setting between
28-32 psi (the machine will not operate correctly if
the AXV is set lower than 28 psi).
6.
Set the lemon ice AXV on the right side of the
machine. With the system still running product,
turn the lemon ice switch on. The AXV is located
behind the cylinder in front of the machine. Set
the lemon ice AXV for 38-42 psi.
7.
When testing is done, take the cylinders apart
and clean the custard machine. Refer Section 3
for details.