Vollrath SU444 Water Cooled User Manual
Page 8

Owner’s Manual #513684
2
SU444I2 Model Machines
1.2 SPECIFICATIONS
SU444 I2 Water Cooled
SU444 I2 Air Cooled
Dimensions
Machine
with crate
Machine
with crate
width
26-3/4’’ (67,9 cm)
34’’ (86,4 cm)
26-3/4’’ (67,9 cm)
34’’ (86,4 cm)
height
67-1/2’’ (171,5 cm)
78’’ (198,1 cm)
67-1/2’’ (171,5 cm)
78’’ (198,1 cm)
depth
40’’ (101,6 cm)
48’’ (121,9 cm)
40’’ (101,6 cm)
48’’ (121,9 cm)
Weight
760 lbs (344,7 kg) 908 lbs (411,8 kg) 760 lbs (344,7 kg) 908 lbs (411,8 kg)
Electrical
1 PH
3 PH
1 PH
3 PH
left
right
left
right
left
right
left
right
minimum circuit
ampacity
35A
27A
23A
19A
35A
27A
24A
20A
maximum overcurrent
protection device
50A
40A
31A
26A
51A
41A
32A
27A
Compressor
Soft Serve - 19,000 Btu/hr Scroll™ Compressor (R-404A)
Shake - 15,000 Btu/hr Scroll™ Compressor (R-404A)
Cabinet - 1,300 Btu/hr Compressor (R-134a)
Drive Motor
Soft Serve - 2 hp, Shake - 3/4 hp
Cooling
Water cooled units require 1/2” N.P.T.
water and drain fi ttings. Maximum
water pressure of 130 psi. Minimum
water fl ow rate of 3 GPM. Ideal EWT
of 50°-70°F. The machine requires 6”
(15,2 cm) air space on all sides for the
cabinet refrigeration system.
Air cooled units require 6” (15,2 cm) air
space on both sides and back.
Hopper Volume
Two - 8 gallon (30,28 liters)
Freezing Cylinder
Volume
Soft Serve - 1.33 gallon (5,4 liters)
Shake - 2.1 gallon (7,95 liters)