Vollrath O231 Water Cooled User Manual
Page 8

2
1.2
SPECIFICATIONS
Dimensions
width
height
depth
Weight
Electrical
circuit ampacity
(per barrel)
overcurrent protection
device (per barrel)
Compressor
Drive Motor
Cooling
Hopper Volume
Freezing Cylinder
Volume
730 lbs (331,1 kg)
3 PH
O231 Water Cooled
640 lbs (290,2 kg)
1 PH
64-1/2'' (163,8 cm)
33-1/4'' (84,5 cm)
730 lbs (331,1 kg)
3 PH
Machine
26'' (66,0 cm)
O231 Air Cooled
Machine
26'' (66,0 cm)
with crate
40-1/4'' (102,2 cm)
62-1/2'' (158,8 cm)
31-1/2'' (80,0 cm)
Water cooled units require 3/8" N.P.T.
water and drain fittings with 2 inlets and
2 outlets or 1/2" N.P.T. water and drain
fittings with 1 inlet and 1 outlet
Air cooled units require 3" (7,6 cm) air
space at back and sides.
Two - 6.5 gallon (24,7 liters)
Two - 1 gallon (4 quart), 3,79 liters
62-1/2'' (158,8 cm)
31-1/2'' (80,0 cm)
640 lbs (290,2 kg)
1 PH
Freezing Cylinders - Two 14,000 Btu/hr (R-404A)
Storage - 1,300 Btu/hr Compressor (R-134a)
Two - 2 hp
26A minimum
with crate
40-1/4'' (102,2 cm)
64-1/2'' (163,8 cm)
33-1/4'' (84,5 cm)
20A minimum
30A maximum
40A maximum
19A minimum
30A maximum
27A minimum
40A maximum