3/2 Shut-off valves
C01GG
3/2 Shut-off valves
C01GJ
3/2 Shut-off valves
C01GH
3/2 Shut-off valves
C01GF
B
C
C1
E
G
N
O
Model
R1/8
71
40,5
19
8
18,5
18
14
C01GG1818
R1/4
77
40,5
19
10
18,5
18
14
C01GG2828
R3/8
81
41
24
11
21,5
21
17
C01GG3838
R1/2
90
41
24
14
21,5
21
21
C01GG4848
ØA
B
C
C1 *
C2
E
G
N
O *
Model
6
R1/8
62
40,5
26
19
8
18,5
18
14
C01GH0618
6
R1/4
65
40,5
26
19
10
18,5
18
14
C01GH0628
6
R3/8
66
40,5
26
19
11
18,5
21
17
C01GH0638
8
R1/8
63
40,5
27,5
19
8
18,5
18
14
C01GH0818
8
R1/4
66
40,5
27,5
19
10
18,5
18
14
C01GH0828
8
R3/8
67
40,5
27,5
19
11
18,5
21
17
C01GH0838
10
R1/4
67
41
31
24
10
21,5
18
17
C01GH1028
10
R3/8
71,5
41
31
24
11
21,5
21
17
C01GH1038
10
R1/2
74,5
41
31
24
14
21,5
21
21
C01GH1048
12
R1/4
75,5
41
34
24
10
21,5
18
19
C01GH1228
12
R3/8
76,5
41
34
24
11
21,5
21
19
C01GH1238
12
R1/2
79,5
41
34
24
14
21,5
21
21
C01GH1248
* see drawing C01GG series
ØA
B
C
C1 *
C2
E
G
N
O *
Model
6
R1/8
62
40,5
26
19
8
18,5
18
14
C01GJ0618
6
R1/4
65
40,5
26
19
10
18,5
18
14
C01GJ0628
6
R3/8
66
40,5
26
19
11
18,5
21
17
C01GJ0638
8
R1/8
65
40,5
27,5
19
8
18,5
18
14
C01GJ0818
8
R1/4
66
40,5
27,5
19
10
18,5
18
14
C01GJ0828
8
R3/8
67
40,5
27,5
19
11
18,5
21
17
C01GJ0838
10
R1/4
70,5
41
31
24
10
21,5
18
17
C01GJ1028
10
R3/8
71,5
41
31
24
11
21,5
21
17
C01GJ1038
10
R1/2
74,5
41
31
24
14
21,5
21
21
C01GJ1048
12
R1/4
75,5
41
34
24
10
21,5
18
19
C01GJ1228
12
R3/8
76,5
41
34
24
11
21,5
21
19
C01GJ1238
12
R1/2
79,5
41
34
24
14
21,5
21
21
C01GJ1248
* see drawing C01GG series
ØA
C
C1 *
E
N
O *
Model
6
52,5
40,5
19
18,5
18
C00GF0600
8
53
40,5
19
18,5
18
C00GF0800
10
62
41
24
21,5
21
C00GF1000
12
68,5
41
24
21,5
21
C00GF1200
* see drawing C01GG series
1
Exhaust bore hole
Warning
These products are intended for use in industrial compressed air
systems only. Do not use these products where pressures and
temperatures can exceed those listed under »Technical features«.
Before using these products with fluids other than those specified,
for non-industrial applications, life-support systems, or other ap-
plications not within published specifications, consult NORGREN.
Through misuse, age, or malfunction, components used in
fluid power systems can fail in various modes.
The system designer is warned to consider the failure modes
of all component parts used in fluid power systems and to provide
adequate safeguards to prevent personal injury or damage to
equipment in the event of such failure.
System designers must provide a warning to end users in
the system instructional manual if protection against
a failure mode cannot be adequately provided.
System designers and end users are cautioned to review specific
warnings found in instruction sheets packed and shipped with
these products.
C
E
ø 4,3
N
B
C 1
G
O
1
2
1
C
E
ø 4,3
N
B
G
C2
ø
A
C
E
ø 4,3
2
1
N
B
G
C2
ø
A
C
E
1
2
ø
A
ø 4,3
N