beautypg.com

B74g excelon general purpose filter/regulator, B74g – Norgren Filter/Regulators User Manual

Page 8

background image

See Section ALE-24 for Accessories

Littleton, CO USA

Phone 303-794-2611

www.norgren.com

B74G

EXCELON design allows in-line or modular
installation

Quick release bayonet bowl

Highly visible, prismatic liquid level indicator lens

Full flow gauge ports

Balanced valve design minimizes effect of variation
in the inlet pressure on the outlet pressure

Modular installations with EXCELON 72, 73, and 74
series can be made to suit particular applications

Excelon® 74 Series Filter/Regulator

3/8", 1/2", 3/4" Port Sizes

ALE-12-8

Ordering Information.

Models listed include PTF threads, knob adjustment, automatic drain, metal bowl with liquid level indicator, 40 µm element,

relieving diaphragm, 5 to 150 psig (0.3 to 10 bar) outlet pressure adjustment range*, with gauge.

† Typical flow with 150 psig (10 bar) inlet pressure, 90 psig (6.3 bar) set pressure and a 15 psig (1 bar) droop from set.

Main Port Size

Model Number

Flow

scfm (dm

3

/s)

Weight lb (kg)

3/8"

B74G-3AK-AD3-RMG

163 (77)

2.62 (1.19)

1/2"

B74G-4AK-AD3-RMG

212 (100)

2.59 (1.17)

3/4"

B74G-6AK-AD3-RMG

212 (100)

2.55 (1.16)

Alternative Models

B 7 4

-

G

★ ★

-

Threads

Substitute

PTF

A

ISO Rc taper

B

ISO G parallel

G

Adjustment

Substitute

Knob

K

T-bar

T

Diaphragm

Substitute

Relieving

R

Non relieving

N

Gauge

Substitute

With

G

Without

N

Outlet Pressure
Adjustment Range*

Substitute

5 to 60 psig (0.3 to 4 bar)

F

5 to 150 psig(0.3 to 10 bar )

M

10 to 250 psig (0.7 to 17 bar )**

S

Bowl

Substitute

Metal with liquid level indicator

D

Transparent with guard

P

Element

Substitute

5 µm

1

25 µm

2

40 µm

3

-

* Outlet pressure can be adjusted to pressures in excess of, and less than, those

specified. Do not use these units to control pressures outside of the specified

ranges.

** Units with 250 psig (17 bar) outlet pressure range are available only with the T-

bar adjustment; therefore substitute T at the 7th digit and S at the 12th position.

Drain

Substitute

Automatic

A

Manual, 1/4 turn

Q

Port Size

Substitute

3/8"

3

1/2"

4

3/4"

6