B64g – Norgren Filter/Regulators User Manual
Page 10
![background image](/manuals/467552/10/background.png)
See Section ALE-24 for Accessories
Littleton, CO USA
Phone 303-794-2611
www.norgren.com
B64G
●
Olympian Plus plug in design
●
High Efficiency water and particle removal
●
Quick release bayonet bowl
●
High visibility prismatic sight glass
●
Push to lock adjusting knob with tamper resistant
option
Olympian Plus Filter/Regulator
1/4", 3/8", 1/2", 3/4" Port Sizes
ALE-12-10
Ordering Information.
Models listed include PTF threads, knob adjustment, automatic drain, metal bowl, 40 µm element, relieving diaphragm, 5 to 150
psig (0.3 to 10 bar) outlet pressure adjustment range* with gauge.
† Typical flow with 150 psig (10 bar) inlet pressure, 90 psig (6.3 bar) set pressure and a 15 psig (1 bar) droop from set.
Port Size
Model
Flow
†
scfm (dm
3
/s)
Weight lb (kg)
1/4"
B64G-2AK-AD3-RMG
64 (30)
3.80 (1.71)
3/8"
B64G-3AK-AD3-RMG
161 (76)
3.76 (1.69)
1/2"
B64G-4AK-AD3-RMG
225 (106)
3.69 (1.66)
3/4"
B64G-6AK-AD3-RMG
225 (106)
4.49 (2.02)
Alternative Models
B 6 4
-
G
★ ★
-
★
★
★
★
Port Size
Substitute
1/4"
2
3/8"
3
1/2"
4
3/4"
6
No Yoke
N
Threads
Substitute
PTF
A
ISO Rc taper
B
ISO G parallel
G
Diaphragm
Substitute
Relieving
R
Non relieving
N
Element
Substitute
5 µm
1
25 µm
2
40 µm
3
Adjustment
Substitute
Knob
K
T-bar
T
Bowl
Substitute
Metal with liquid level indicator
D
Guarded Transparent
P
-
★
★
★
Drain
Substitute
1/4 turn manual
Q
Automatic
A
Gauge
Substitute
With
G
Without
N
Outlet Pressure Adjustment Range*
Substitute
5 to 60 psig (0.3 to 4 bar)
F
5 to 150 psig (0.3 to 10 bar)
M
10 to 250 psig (0.7 to 17 bar)
S**
* Outlet pressure can be adjusted to pressures in excess of, and less than, those
specified. Do not use these units to control pressures outside of the specified ranges.
**
Units with 250 psig (17 bar) adjustment range are available only with the T-bar
adjustment; therefore substitute T at the 7th digit and S at the 12th position.