Norgren B64G Series User Manual
B64g
7/97
N/AL.8.240.300.01
B64G
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
Ordering Information
See
Ordering Information on the following
pages.
ISO Symbols
Automatic Drain
Relieving
Manual Drain
Relieving
Olympian Plus
Filter/Regulator
1/4
"
, 3/8
",
1/2
"
, 3/4
"
Port Sizes
●
Olympian Plus plug in design
●
High Efficiency water and particle removal
●
Quick release bayonet bowl
●
High visibility prismatic sight glass*
●
Push to lock adjusting knob with tamper resistant
option
* UK and other patents pending
Technical Data
Fluid: Compressed air
Maximum pressure:
Guarded transparent bowl: 10 bar (150 psig)
Metal bowl: 17 bar (250 psig)
Operating temperature*:
Guarded transparent bowl: -20° to +50°C (0° to +125°F)
Metal bowl: -20° to +80°C (0° to +175°F)
* Air supply must be dry enough to avoid ice formation at temperatures below +2°C
(+35°F).
Partical removal: 5, 25 or 40 µm. Within ISO 8573-1, Class 3 and
Class 5
Typical flow at 6,3 bar (90 psig) inlet pressure:
106 dm
3
/s (225 scfm)
Automatic drain connection: 1/8
"
Automatic drain operating conditions:
Minimum pressure: 0,7 bar (10 psig).
Drain opens when bowl pressure drops below 0,2 bar (3 psig).
Minimum air flow: 1 dm
3
/s (2 scfm) required to close drain.
Gauge Ports:
1/8
" PTF with PTF main ports
1/8
" ISO Rc with ISO Rc main ports
1/8
" ISO Rc with ISO G main ports
Nominal bowl size:
0,2 litre (7 fluid ounce)
Materials:
Body: Zinc
Bonnet: Aluminium
Valve: Brass
Yoke: Zinc
Metal bowl: Aluminium
Standard metal bowl prismatic liquid level indicator lens:
Grilamid
Optional metal bowl sight glass: Pyrex
Optional transparent bowl: Polycarbonate
Element: Sintered plastic
Elastomers: Synthetic rubber
Automatic Drain
Non Relieving
Manual Drain
Non Relieving
Back to Selector Page