beautypg.com

Approvals – Norgren 97100 NAMUR Series User Manual

Page 2

background image

N/en 5.4.372.02

97100 NAMUR

Our policy is one of continued research and development. We therefore reserve the right to amend,

without notice, the specifications given in this document. © 2013 Norgren GmbH

2004-5152c

9/13

Solenoid operators for standard version 971xxx0 only

Technical data

Standard version, 5/2 or 3/2 indirect acting valves (conversion instructions see page 6)

Symbol

Por size

1

3, 5

2, 4

Actuation

Operating

pressure (bar)

Flow

(l/min)

Weight

(kg)

Dimension

No.

Model *1)

G 1/4

G 1/8

Flange

Solenoid/spring

2 ... 8

750

0,25

1

9710000

1/4 NPT

1/8 NPT

Flange

Solenoid/spring

2 ... 8

750

0,25

1

9710010

G 1/4

G 1/8

Flange

Solenoid/solenoid

2 ... 8

750

0,35

2

9711000

1/4 NPT

1/8 NPT

Flange

Solenoid/solenoid

2 ... 8

750

0,35

2

9711010

G 1/4

G 1/8

Flange

Solenoid/solenoid

mid position APB

2 ... 8

500

0,40

3

9712000

1/4 NPT

1/8 NPT

Flange

Solenoid/solenoid

mid position APB

2 ... 8

500

0,40

3

9712010

*1) When ordering please indicate solenoid, voltage and current type (frequency).

Valve function: APB = All Ports Blocked

4

2

3

1

5

5

2

4

1

5

3

52 EMH

H

4

2

3

1

5

1

5

3

2

4

4

2

5 1 3

MR

Approvals

Model

Approvals

ATEX IECEx FM

Datasheet

304x

PTB 06 ATEX 2055

N/de 7.1.555

306x

PTB 03 ATEX 2015

N/en 7.1.560

307x

EC-Declaration of Conformity —

N/en 7.1.565

1,8

70

IP 65 (with connector)

-15 ... +50

Connector

DIN EN 175301-803

Form B *6)

0,1

11

1

3050

1,6

3,5

30

IP 65 (with connector)

-15 ... +50

Steckverbinder

DIN EN 175301-803

Form A *6)

0,1

12

1

3036

2

85

II3G

II3D

Ex nA IIC T5 Gc

Ex tc IIIC T95° Dc

IP 65 (with connector)

-15 ... +50

With special

connector

DIN EN 175301-803

Form A

0,3

12

1

3046

2,0

18

II3G

II3D

Ex nA IIC T5 Gc

Ex tc IIIC T95° Dc

IP 65 (with connector)

-15 ... +50

With special

connector

DIN EN 175301-803

Form A

0,3

12

1

3047

5,0

22

II2G

II2D

Ex mb IIC T4/T5 Gb

Ex mb IIC T4 Gb

Ex mb tb T130°C Db

IP65 (with connector)

-20 ... +50

3 m cable

0,3

13

15

3061

2,7

115

II2G

II2D

Ex mb IIC T5 Gb

Ex mb tb T95°C Db

IP65 (with connector)

-20 ... +50

3 m cable

0,3

13

14

3062

2,7

115

IP 66 (with connector)

-10 ... +50

Connector M12x1,

DIN IEC 61076-2-101

*6)

Solenoid with yellow

LED

0,1

14

17

3071

Standard voltages (±10%) 24 V d.c., 230 V a.c. Further versions on request.
*6) Connector is not scope of delivery, see table »Accessories«

Power consumption

24 V d.c. 230 V a.c.

(W) (VA)

Rated current

24 V d.c. 230 V a.c.

(m A) (m A)

Ex-Protection IP-Protection class

(to EN 60529)

Temperature

Ambient/Fluid

(°C)

Electrical

connection

Weight

(kg)

Dimension

Nr.

Circuit

diagram

Nr.

Model

Ex-Protection

(ATEX-Category)