Approvals – Norgren 97100 NAMUR Series User Manual
Page 2
N/en 5.4.372.02
97100 NAMUR
Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document. © 2013 Norgren GmbH
2004-5152c
9/13
Solenoid operators for standard version 971xxx0 only
Technical data
Standard version, 5/2 or 3/2 indirect acting valves (conversion instructions see page 6)
Symbol
Por size
1
3, 5
2, 4
Actuation
Operating
pressure (bar)
Flow
(l/min)
Weight
(kg)
Dimension
No.
Model *1)
G 1/4
G 1/8
Flange
Solenoid/spring
2 ... 8
750
0,25
1
9710000
1/4 NPT
1/8 NPT
Flange
Solenoid/spring
2 ... 8
750
0,25
1
9710010
G 1/4
G 1/8
Flange
Solenoid/solenoid
2 ... 8
750
0,35
2
9711000
1/4 NPT
1/8 NPT
Flange
Solenoid/solenoid
2 ... 8
750
0,35
2
9711010
G 1/4
G 1/8
Flange
Solenoid/solenoid
mid position APB
2 ... 8
500
0,40
3
9712000
1/4 NPT
1/8 NPT
Flange
Solenoid/solenoid
mid position APB
2 ... 8
500
0,40
3
9712010
*1) When ordering please indicate solenoid, voltage and current type (frequency).
Valve function: APB = All Ports Blocked
4
2
3
1
5
5
2
4
1
5
3
52 EMH
H
4
2
3
1
5
1
5
3
2
4
4
2
5 1 3
MR
Approvals
Model
Approvals
ATEX IECEx FM
Datasheet
304x
PTB 06 ATEX 2055
—
—
N/de 7.1.555
306x
PTB 03 ATEX 2015
—
—
N/en 7.1.560
307x
EC-Declaration of Conformity —
—
N/en 7.1.565
1,8
—
70
—
—
IP 65 (with connector)
-15 ... +50
Connector
DIN EN 175301-803
Form B *6)
0,1
11
1
3050
1,6
3,5
30
—
—
IP 65 (with connector)
-15 ... +50
Steckverbinder
DIN EN 175301-803
Form A *6)
0,1
12
1
3036
2
—
85
—
II3G
II3D
Ex nA IIC T5 Gc
Ex tc IIIC T95° Dc
IP 65 (with connector)
-15 ... +50
With special
connector
DIN EN 175301-803
Form A
0,3
12
1
3046
—
2,0
—
18
II3G
II3D
Ex nA IIC T5 Gc
Ex tc IIIC T95° Dc
IP 65 (with connector)
-15 ... +50
With special
connector
DIN EN 175301-803
Form A
0,3
12
1
3047
—
5,0
—
22
II2G
II2D
Ex mb IIC T4/T5 Gb
Ex mb IIC T4 Gb
Ex mb tb T130°C Db
IP65 (with connector)
-20 ... +50
3 m cable
0,3
13
15
3061
2,7
—
115
—
II2G
II2D
Ex mb IIC T5 Gb
Ex mb tb T95°C Db
IP65 (with connector)
-20 ... +50
3 m cable
0,3
13
14
3062
2,7
—
115
—
—
IP 66 (with connector)
-10 ... +50
Connector M12x1,
DIN IEC 61076-2-101
*6)
Solenoid with yellow
LED
0,1
14
17
3071
Standard voltages (±10%) 24 V d.c., 230 V a.c. Further versions on request.
*6) Connector is not scope of delivery, see table »Accessories«
Power consumption
24 V d.c. 230 V a.c.
(W) (VA)
Rated current
24 V d.c. 230 V a.c.
(m A) (m A)
Ex-Protection IP-Protection class
(to EN 60529)
Temperature
Ambient/Fluid
(°C)
Electrical
connection
Weight
(kg)
Dimension
Nr.
Circuit
diagram
Nr.
Model
Ex-Protection
(ATEX-Category)