Mountings and service kits, Magnetically operated switches connectors – Norgren PRA/862000/M IVAC Industrial cylinder User Manual
Page 5
PRA/862000/M
N/us 1.5.250.05
4/13
Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
© Norgren, Inc. 2013
Mountings and service kits
Model
Ø
A
10
Page 7
AK
18
Page 7
B, G
1
Page 8
C
2
Page 8
D
5
Page 9
D2
7
Page 9
F
15
Page 9
FH
9
Page 8
R
3
Page 10
32
QM/8032/35
QM/8025/38
QA/8032/22
QA/8032/21
QA/8032/23
QA/8032/42
QM/8025/25
QA/8032/34
QA/8032/27
40
QM/8032/35
QM/8040/38
QA/8040/22
QA/8040/21
QA/8040/23
QA/8040/42
QM/8040/25
QA/8040/34
QA/8040/27
50
QM/8050/35
QM/8050/38
QA/8050/22
QA/8050/21
QA/8050/23
QA/8050/42
QM/8050/25
QA/8050/34
QA/8050/27
63
QM/8050/35
QM/8050/38
QA/8063/22
QA/8063/21
QA/8063/23
QA/8063/42
QM/8050/25
QA/8063/34
QA/8063/27
80
QM/8080/35
QM/8080/38
QA/8080/22
QA/8080/21
QA/8080/23
QA/8080/42
QM/8080/25
QA/8080/34
QA/8080/27
100
QM/8080/35
QM/8080/38
QA/8100/22
QA/8100/21
QA/8100/23
QA/8100/42
QM/8080/25
QA/8100/34
QA/8100/27
Corrosion protected mounts
PVQA/8032/22
PVQA/8032/23
PVQM/8025/25
PVQA/8032/33
PVQA/8040/22
PVQA/8040/23
PVQM/8040/25
PVQA/8040/33
PVQA/8050/22
PVQA/8050/23
PVQM/8050/25
PVQA/8040/33
PVQA/8063/22
PVQA/8063/23
PVQM/8050/25
PVQA/8063/33
PVQA/8080/22
PVQA/8080/23
PVQM/8080/25
PVQA/8080/33
PVQA/8100/22
PVQA/8100/23
PVQM/8080/25
PVQA/8100/33
Model
Ø
S
12
Page 10
SS
16
Page 12
SW
6
Page 11
UF
17
Page 10
UR
4
Page 11
US
8
Page 12
Service kit
32
QA/8032/41
M/P19931
M/P19493
QM/8025/32
QA/8032/33
M/P40310
PRQA/862032/00
40
QA/8040/41
M/P19932
M/P19494
QM/8040/32
QA/8040/33
M/P40311
PRQA/862040/00
50
QA/8040/41
M/P19933
M/P19495
QM/8050/32
QA/8050/33
M/P40312
PRQA/862050/00
63
QA/8063/41
M/P19934
M/P19496
QM/8050/32
QA/8063/33
M/P40313
PRQA/862063/00
80
QA/8063/41
M/P19935
M/P19497
QM/8080/32
QA/8080/33
M/P40314
PRQA/862080/00
100
QA/8100/41
M/P19936
M/P19498
QM/8080/32
QA/8100/33
M/P40315
PRQA/862100/00
Magnetically operated switches
Connectors
Model
Reed *3)
Solid state
Voltage *2)
(V a.c.)
(V d.c.)
Current max.
(mA)
Temperature
°F (°C)
LED
Features
Cable length
(m)
Cable
type
Cable with
connector
Data sheet
M/50/LSU/*V
–
10 ... 240
10 ... 170
180
-4° to 176° (-20° to 80°)
•
–
2, 5 or 10
PVC 2 x 0.25
–
N/en 4.3.005
M/50/LSU/5U
–
10 ... 240
10 ... 170
180
-4° to 176° (-20° to 80°)
•
–
5
PUR 2 x 0.25
–
N/en 4.3.005
TM/50/RAU/2S
–
10 ... 240
10 ... 170
180
-4° to 302° (-20° to150°)
–
–
2
Silicone 2 x 0.25 –
N/en 4.3.005
M/50/RAC/5V
–
10 ... 240
10 ... 170
180
-4° to 176° (-20° to 80°)
–
Changeover
5
PVC 3 x 0.25
–
N/en 4.3.005
M/50/LSU/CP
–
10 ... 60
10 ... 75
180
-4° to 176° (-20° to 80°)
•
Plug M8x1
5
PVC 3 x 0.25
M/P73001/5
N/en 4.3.005
–
M/50/EAP/*V
–
10 ... 30
150
-40° to 176° (-40° to 80°) *1)
•
PNP
2, 5 or 10
PVC 3 x 0.25
–
N/en 4.3.007
–
M/50/EAP/CP
–
10 ... 30
150
-40° to 176° (-40° to 80°) *1)
•
PNP, Plug M8x1
5
PVC 3 x 0.25
M/P73001/5
N/en 4.3.007
–
M/50/EAP/CC
–
10 ... 30
150
-40° to 176° (-40° to 80°) *1)
•
PNP, Plug M12x1
5
PVC 3 x 0.25
M/P34614/5
N/en 4.3.007
–
M/50/EAN/*V
–
10 ... 30
150
-40° to 176° (-40° to 80°) *1)
•
NPN
2, 5 or 10
PVC 3 x 0.25
–
N/en 4.3.007
–
M/50/EAN/CP
–
10 ... 30
150
-40° to 176° (-40° to 80°) *1)
•
NPN, Plug M8x1
5
PVC 3 x 0.25
M/P73001/5
N/en 4.3.007
* Please insert cable length
*1) -40°F to 176°F (-40°C to 80°C) protection class IP65; -4°F to 176°F (-20°C to 80°C) protection class IP67 and IP68, details see data sheet
*2) Supply voltage 24 V d.c. (± 10%) max for P.A/86200/M only *3) For use with 32 mm bore - consult factory.
Plug with cable gland
22
Plug with molded cable
21
V10027-D00
V10014-D01 (LED and VDR, cable length 1 m)
V10012-D13 (LED and VDR)
V10014-D03 (LED and varistor, cable length 3 m)