beautypg.com

Figure 7, Illustrate, Cs5581 – Cirrus Logic CS5581 User Manual

Page 18: Cs5571

background image

CS5581

18

DS796PP1

3/25/08

14:34

The following figure depicts the CS5581 part powered from a single 5V analog supply and configured for
unipolar measurement.

Figure 7. CS5581 Configured for Unipolar Measurement Using

a Single 5V Analog Supply

ACOM

AIN

SMODE

CS

4

SCLK

4

SDO

RDY

CONV

BP/UP

MCLK

RST

TST

VREF-

VREF+

+4.096

Voltage

Reference

(NOTE 1)

+5 V

BUFEN

1. See Section 3.3 Voltage Reference for information on
required voltage reference performance criteria.
2. Locate capacitors so as to minimize loop length.
3. V1-, V2-, and VLR should be connected to the same
ground plane under the chip.
4. SCLK and SDO may require pull-down resistors in
some applications.

NOTES

0.1 µF

(V-) Buffers Off

(V+) Buffers On

0.1 µF

10 µF

V1+

V2+

V1-

V2-

VL

VLR

DCR

+5 V

+3.3 V to 1.8 V

0.1 µF

0.1 µF

X7R

0.1 µF

10

49.9

150pF

2k

4700pF

C0G

0 V to +2.048 V

CS5571

VLR2

50

VLR3

CS3003 / CS3004

CS5581