beautypg.com

Pwm filter characteristics, Switching characteristics - xti, Figure 2. xti timings – Cirrus Logic CS44600 User Manual

Page 11: Figure 2.xti timings

background image

DS633F1

11

CS44600

PWM FILTER CHARACTERISTICS

(Logic “0” = GND = 0 V; Logic “1” = VLS = VLC; VD = 2.5 V; DAI_MCLK = 12.288 MHz; XTAL = 24.576 MHz; PWM
Switch Rate = 384 kHz; Fs = 32 kHz to 192 kHz; Measurement bandwidth is 10 Hz to 20 kHz unless otherwise
specified.)

12. Filter response is not production tested but is characterized and guaranteed by design.

13. XTAL = 49.152 MHz; PWM Switch Rate = 768 kHz; Fs = 96 kHz to 192 kHz.

14. The equation for the group delay through the sample rate converter with OSRATE = 0b is (8.5 / Fsi) + (10

/ Fso) ± (4.5 / Fsi). The equation for the group delay through the sample rate converter with OSRATE = 1b
is (8.5 / Fsi) + (20 / Fso) ± (4.5 / Fsi).

SWITCHING CHARACTERISTICS - XTI

(VD = 2.5 V, VDP = VLC = VLS = 3.3 V, VDX = 2.5 V to 5.0 V; Inputs: Logic 0 = GND, Logic 1 = VDX)

Parameter

Unit

Min Typ

Max

Digital Filter Response

(Note 12)

Passband
OSRATE = 0b

to -0.01 dB corner

to -3 dB corner

OSRATE = 1b

(Note 13)

to -0.01 dB corner

to -3 dB corner

0
0
0
0

-
-
-
-

1.6

24.0

3.3

44.5

kHz
kHz
kHz
kHz

Frequency Response

OSRATE = 0b

10 Hz to 20 kHz

OSRATE = 1b

(Note 13)

10 Hz to 40 kHz

-0.8
-1.2

-
-

+0.02
+0.02

dB
dB

Group Delay

(Note 14)

ms

De-emphasis Error

Fs = 32 kHz

(Relative to 1 kHz)

Fs = 44.1 kHz

Fs = 48 kHz

-
-
-

-
-
-

±0.23
±0.14
±0.09

dB
dB
dB

Parameter

Symbol

Min

Typ

Max

Unit

XTI period

t

clki

18.518

---

40.69

ns

XTI high time

t

clkih

8.34

---

22.38

ns

XTI low time

t

clkil

8.34

---

22.38

ns

XTI Duty Cycle

45

50

55

%

External Crystal operating frequency

24.576

---

54

MHz

XTI

t

clkih

t

clkil

t

clki

Figure 2. XTI Timings