Figure 3. i2c control port timing, Switching characteristics - control port - i, C mode (cs4221) – Cirrus Logic CS4221 User Manual
Page 9

CS4220 CS4221
DS284PP3
9
SWITCHING CHARACTERISTICS - CONTROL PORT - I
2
C MODE (CS4221)
(T
A
= 25° C; VA, VD = 4.75 V - 5.25 V; Inputs: Logic 0 = DGND, Logic 1 = VD; C
L
= 30 pF)
Notes: 15. Not tested but guaranteed by design.
16. Data must be held for sufficient time to bridge the 300 ns transition time of SCL.
Parameter
Symbol
Min
Max
Unit
I
2
C
®
Mode (SPI/I2C = 1)
SCL Clock Frequency
f
scl
-
100
kHz
RST rising edge to Start
(Note 15)
t
irs
50
-
µs
Bus Free Time between transmissions
t
buf
4.7
-
µs
Start Condition Hold Time (prior to first clock pulse)
t
hdst
4.0
-
µs
Clock Low Time
t
low
4.7
-
µs
Clock High Time
t
high
4.0
-
µs
Setup time for repeated Start Condition
t
sust
4.7
-
µs
SDA hold time for SCL falling
(Note 16)
t
hdd
0
-
µs
SDA setup time to SCL rising
t
sud
250
-
ns
Rise time of SCL
t
rc
-
25
ns
Fall time of SCL
t
fc
-
25
ns
Rise time of SDA
t
rd
-
1
µs
Fall time of SDA
t
fd
-
300
ns
Setup time for Stop Condition
t
susp
4.7
-
µs
t
buf
t
hdst
t
hdst
t
low
t rc
t fc
t
hdd
t high
t sud
t sust
t susp
Stop
Start
Start
Stop
Repeated
SDA
SCL
t
irs
RST
t rd
t fd
Figure 3. I
2
C Control Port Timing