beautypg.com

Differential pressure gauge – WIKA 732.15.160 User Manual

Page 7

background image

11224380.02B

A



11265191.07 12/2012 GB/D/F/I

WIKA operating instructions differential pressure gauge models 712.15.160, 732.15.160

7

GB

1. The span adjustment, situated at the ‚4 o‘clock‘ point on the instrument case, is accessible

through the case by removing the cover cap.

2. Charge the instrument to the desired nominal pressure.
3. To set the pointer to the span value, using an allen key (size 3 mm) inserted into the funnel,

turn it either clockwise (reduce the measuring range) or anticlockwise (expand the measu-

ring range). The gauge will then be fully adjusted to the required measuring range.

4. If the gauge is equipped with a transmitter Model 89x.44, then this procedure will also

adjust the output signal to the new measuring range.

5. After completing the adjustment the equipment should be resealed with the cover cap.

Interchangeable scales (optional)

1. Loosen the clamp clip on the case of the

differential pressure gauge and remove the

cover ring complete with the lens.

2. Loosen and remove the knurled screw.

3. Remove all three scales, place the desired

scale on top and put them back in place.

4. Reinsert the knurled screw and tighten it.

Mount the cover ring and lens and fasten

the clamp clips again.

Additional pressure connections

„

Three additional G ¼ female threads are

available on the minus measurement chamber

(the right measuring cell flange when viewed

from the back) e.g. for connecting a pressure

switch, safety valve or A-10 Cryo or IS-20

transmitters

„

Two G ¼ female threads are available on

the plus measurement chamber (the left cell

flange when viewed from the back) e.g. for

recalibration

4. Differential pressure gauge

Legend



Clamp clip

Cover ring

Knurled screw

Scales

G 1/4 pressure connections

Mounting holes M8

G 1/4 pressure connections