Switch contacts . disposal, Maintenance, Disposal – WIKA 732.15.160 User Manual
Page 16
16
11265191.07 12/2012 GB/D/F/I
WIKA operating instructions differential pressure gauge models 712.15.160, 732.15.160
GB
10. Switch contacts ... 12. Disposal
11. Maintenance
WIKA differential pressure gauges require no maintenance or servicing and will give very long
service when handled and operated properly.
12. Disposal
Incorrect disposal can put the environment at risk.
Dispose of instrument components and packaging materials in an environmentally compatible
way and in accordance with the country-specific waste disposal regulations.
Terminal configuration
Magnetic snap-action
contacts:
Single contact,
NS 100
Double contact,
NS 100
Single contact,
NS 160
Double contact,
NS 160
Inductive alarm sensors:
Single contact,
NS 100 and 160
Double contact,
NS 100 and 160
green/yellow
blue
blue
brown
brown
brown
black
black
1st contact
common
1st contact
common
2nd contact
common
2nd contact
yellow
white
black
1st contact +
white
yellow
violet
1st contact -
1st contact +
1st contact -
2nd contact -
2nd contact +
green/yellow
green/yellow
green/yellow
green/yellow
green/yellow
blue
brown
black
1st contact
common
2nd contact
green/yellow
green/yellow