beautypg.com

Transmitter for working pressure indication – WIKA 732.15.160 User Manual

Page 13

background image

11265191.07 12/2012 GB/D/F/I

WIKA operating instructions differential pressure gauge models 712.15.160, 732.15.160

13

GB

Specifications

A-10

IS-20

Data sheet

PE 81.60

PE 81.50

Design

standard

intrinsically safe

Pressure ranges

bar

0 ... 6 to 0 ... 60

0 ... 6 to 0 ... 60

Outputs

mA

4 ... 20

4 ... 20 (line transformer)

Medium temperature

°C

-30 ... +100

-20 ... +80

Ambient temperature

°C

-30 ... +100

-20 ... +80

Wetted parts

stainless steel

stainless steel

Power supply U

B

DC

8 V < U

B

≤ 30 V

10 V < U

B

≤ 30 V

Maximum load R

A

Ohm

R

A

≤ (U

B

- 8 V) / 0.02 A R

A

≤ (U

B

- 10 V) / 0.02 A

Accuracy

BFSL

% of span

≤ 0.5

≤ 0.25

Compensated temperature

range

°C

0 ... +80 °C

0 ... +80 °C

Wiring details,

2-wire

The corresponding operating instructions are included in the delivery

of each differential pressure gauge with integrated transmitter for

working pressure indication.

Non hazardous

area

Hazardous

(classified) area

9. Transmitter for working pressure indication

9. Transmitter for working pressure indication (optional)

Standard version model A-10

or Ex version model IS-20

Transmitter for working

pressure indication

The transmitters for the working pressure

are screwed in sideways, on the left side of

the minus measurement chamber and can,

if necessary, be retrofitted on-site.

Pressure connection for Transmitter: G 1/4

(male)

This manual is related to the following products: