beautypg.com

Safety . installation – WIKA 732.15.160 User Manual

Page 4

background image

4

11265191.07 12/2012 GB/D/F/I

WIKA operating instructions differential pressure gauge models 712.15.160, 732.15.160

GB

1. Safety ... 3. Installation

2. General information

These operating instructions are based upon the following:

„

EN 837-2: Selection and installation recommendations for pressure gauges

„

Data sheet PM 07.30: Differential pressure gauges models 712.15.160, 732.15.160

„

Data sheet PM 02.01, PM 02.02, PM 02.04: Bourdon tube pressure gauges

3. Installation

The installation of the differential pressure gauge should be carried out in accordance with the

installation recommendations for pressure gauges per EN 837-2 /7.

„

Prior to the installation of the pressure gauge, the pipes should be thoroughly cleaned

„

The pressure gauge should be installed and operated such as to avoid exposure to

vibration.

Mounting by means of - rigid tailpipe and/or

- 4 M8 threaded mounting holes incorporated in the body

„

The pressure gauges should be protected against contamination and high temperature

fluctuations

„

The maximum permissible media/ambient temperature must not be exceeded

Fitting of the pressure connections as per the j and i symbols

j

higher pressure ⇒ bottom pressure (p

B

),

i

lower pressure ⇒ working pressure/overriding pressure (p

D

)

p

B

= p

FL

+ p

D

(with p

FL

= hydrostatic pressure of liquid = r

g

h)

1. Safety

WARNING!

Before installation, commissioning and operation, ensure that the

appropriate differential pressure gauge has been selected in terms of

measuring range, design and specific measuring conditions.

Only work on the gauge with the voltage disconnected.

Non-observance can result in serious injury and/or damage to equipment.

Only appropriately qualified skilled personnel should work on these

instruments.

This manual is related to the following products: