Specifications model n-10 / n-11 – WIKA N-11 User Manual
Page 7
2147614.07 GB/D/F/E 04/2009
1 WIKA Operating instructions/Betriebsanleitung/Mode d'emploi/Instrucciones de servicio N-10, N-11
2147614.07 GB/D/F/E 04/2009
1
WIKA Operating instructions/Betriebsanleitung/Mode d'emploi/Instrucciones de servicio N-10, N-11
Specifications
Model N-10 / N-11
Materials
Wetted parts
(Other materials see WIKA diaphragm seal program)
Model N-10
»
Stainless steel (> 25 bar stainless steel and Elgiloy
®
)
Model N-11
»
Stainless steel
O-ring: NBR {FPM/FKM or EPDM}
Case
Stainless steel
Internal transmission fluid
Synthetic oil (not for N-10 with pressure ranges > 25 bar)
Power supply U
B
U
B
in VDC
10 <
U
B
≤
30 with signal output 4 … 20 mA, 2-wire
10 < U
B
≤ 30 with signal output 1 … 5 V, 3-wire
{low power 6 < UB
≤ 30}
Signal output and
4 ... 20 mA, 2-wire
R
A
≤ (U
B
– 10 V) / 0.02 A
maximum ohmic load RA
R
A
in Ohm
1 ... 5 V, 3-wire
R
A
> 10 k
Response time (10 ... 90 %)
ms
≤
1
Dielectric strength
VDC
500
Accuracy
% of span
≤
0.25
(BFSL)
≤
0.5
3)
3)
Including non-linearity, hysteresis, zero point and full scale error (corresponds to
error of measurement per IEC 61298-2).
Adjusted in vertical mounting position with lower pressure connection.
Non-linearity
% of span
≤
0.2
(BFSL) according to IEC 61298-2
Non-repeatability
% of span
≤
0.1
1-year stability
% of span
≤
0.2
(at reference conditions)
Permissible temperature of
Medium
4)
-30 ... +105 °C
-22 ... +221 °F
Ambience
4)
-30 ... +80 °C
-22 ... +176 °F
Storage
4)
-30 ... +105 °C
-22 ... +221 °F
4)
Also complies with EN 50178, Tab. 7, Operation (C) 4K4H, Storage (D) 1K4,
Transport (E) 2K3
Specifications
Model N-10 / N-11
Compensated temp range
0 ... +80 °C
32 ... +176 °F
Temperature coefficients within
compensated temp range
Mean TC of zero
% of span
≤
0.2 / 10 K
(< 0.4 for pressure range
≤
0,25 bar)
Mean TC of range
% of span
≤
0.2 / 10 K
CE- conformitiy
Pressure equipment directive
97/23/EC
EMC directive
89/336/EEC emission (class B) and immunity according to EN 61 326
Directive ATEX of equipment
intended for use in potentially
explosive atmospheres
94/9/EC
Ex-protection
ATEX
II 3G EEx nA II
II 3D IP65 T80°C
Ignition protection type
EEx nA II 4
EEx nA II T5
EEx nA II T6
Conformity specifications
Power supply UB
VDC
30
30
30
Medium
-30 ... +105 °C
-30 ... +80 °C
-30 ... +60 °C
-22 ... +221 °F
-22 ... +176 °F
-22 ... +140 °F
Ambient
»
M12x1
-25 ... +90 °C
-25 ... +80 °C
-25 ... +60 °C
-13 ... +194 °F
-13 ... +176 °F
-13 ... +140 °F
»
Flying leads
-30 ... +80 °C
-30 ... +80 °C
-30 ... +60 °C
-22 ... +176 °F
-22 ... +176 °F
-22 ... +140 °F
Storage
-30 ... +105 °C
-30 ... +105 °C
-30 ... +105 °C
-22 ... +221 °F
-22 ... +221 °F
-22 ... +221 °F
RF-immunity
V/m
10
Burst
KV
4
Shock resistance
g
1000 according to IEC 60068-2-27 (mechanical shock)
Vibration resistance
g
20 according to IEC 60068-2-6 (vibration under resonance)
7. Starting, operation
GB
7. Starting, operation
GB