beautypg.com

Specifications model n-10 / n-11 – WIKA N-11 User Manual

Page 7

background image

2147614.07 GB/D/F/E 04/2009

1 WIKA Operating instructions/Betriebsanleitung/Mode d'emploi/Instrucciones de servicio N-10, N-11

2147614.07 GB/D/F/E 04/2009

1

WIKA Operating instructions/Betriebsanleitung/Mode d'emploi/Instrucciones de servicio N-10, N-11

Specifications

Model N-10 / N-11

Materials

Wetted parts

(Other materials see WIKA diaphragm seal program)

Model N-10

»

Stainless steel (> 25 bar stainless steel and Elgiloy

®

)

Model N-11

»

Stainless steel
O-ring: NBR {FPM/FKM or EPDM}

Case

Stainless steel

Internal transmission fluid

Synthetic oil (not for N-10 with pressure ranges > 25 bar)

Power supply U

B

U

B

in VDC

10 <

U

B

30 with signal output 4 … 20 mA, 2-wire

10 < U

B

≤ 30 with signal output 1 … 5 V, 3-wire

{low power 6 < UB

≤ 30}

Signal output and

4 ... 20 mA, 2-wire

R

A

≤ (U

B

– 10 V) / 0.02 A

maximum ohmic load RA

R

A

in Ohm

1 ... 5 V, 3-wire

R

A

> 10 k

Response time (10 ... 90 %)

ms

1

Dielectric strength

VDC

500

Accuracy

% of span

0.25

(BFSL)

0.5

3)

3)

Including non-linearity, hysteresis, zero point and full scale error (corresponds to

error of measurement per IEC 61298-2).

Adjusted in vertical mounting position with lower pressure connection.

Non-linearity

% of span

0.2

(BFSL) according to IEC 61298-2

Non-repeatability

% of span

0.1

1-year stability

% of span

0.2

(at reference conditions)

Permissible temperature of
Medium

4)

-30 ... +105 °C

-22 ... +221 °F

Ambience

4)

-30 ... +80 °C

-22 ... +176 °F

Storage

4)

-30 ... +105 °C

-22 ... +221 °F

4)

Also complies with EN 50178, Tab. 7, Operation (C) 4K4H, Storage (D) 1K4,

Transport (E) 2K3

Specifications

Model N-10 / N-11

Compensated temp range

0 ... +80 °C

32 ... +176 °F

Temperature coefficients within

compensated temp range

Mean TC of zero

% of span

0.2 / 10 K

(< 0.4 for pressure range

0,25 bar)

Mean TC of range

% of span

0.2 / 10 K

CE- conformitiy

Pressure equipment directive

97/23/EC

EMC directive

89/336/EEC emission (class B) and immunity according to EN 61 326

Directive ATEX of equipment

intended for use in potentially

explosive atmospheres

94/9/EC

Ex-protection

ATEX

II 3G EEx nA II
II 3D IP65 T80°C

Ignition protection type

EEx nA II 4

EEx nA II T5

EEx nA II T6

Conformity specifications

Power supply UB

VDC

30

30

30

Medium

-30 ... +105 °C

-30 ... +80 °C

-30 ... +60 °C

-22 ... +221 °F

-22 ... +176 °F

-22 ... +140 °F

Ambient

»

M12x1

-25 ... +90 °C

-25 ... +80 °C

-25 ... +60 °C

-13 ... +194 °F

-13 ... +176 °F

-13 ... +140 °F

»

Flying leads

-30 ... +80 °C

-30 ... +80 °C

-30 ... +60 °C

-22 ... +176 °F

-22 ... +176 °F

-22 ... +140 °F

Storage

-30 ... +105 °C

-30 ... +105 °C

-30 ... +105 °C

-22 ... +221 °F

-22 ... +221 °F

-22 ... +221 °F

RF-immunity

V/m

10

Burst

KV

4

Shock resistance

g

1000 according to IEC 60068-2-27 (mechanical shock)

Vibration resistance

g

20 according to IEC 60068-2-6 (vibration under resonance)

7. Starting, operation

GB

7. Starting, operation

GB

This manual is related to the following products: