beautypg.com

Specifications – WIKA MHC-1 User Manual

Page 9

background image

9

WIKA operating instructions pressure transmitter, model MHC-1

14035467.01 08/2012 GB/D/F/E

GB

3. Specifications

3. Specifications

3.1 Measuring ranges

Relative pressure

bar Measuring range 0 ... 60

0 ... 100

0 ... 160

0 ... 250

0 ... 400

0 ... 600

1,000

Overpressure limit 120

200

320

500

800

1,200

1,500

Burst pressure

240

400

640

1,000

1,600

2,400

3,000

psi Measuring range 0 ... 1,000 0 ... 1,500 0 ... 2,000 0 ... 3,000 0 ... 5,000 0 ... 10,000

Overpressure limit 1,740

2,900

4,000

6,000

10,000

17,400

Burst pressure

3,480

5,800

9,280

14,500

23,200

34,800

Vacuum tightness

Yes

3.2 Output signals

Signal type

Signal

CANopen

Device profile DS-404

J1939

SAE J1939

3.3 Voltage supply

Power supply

DC 10 ... 30 V

Total current consumption

< 40 mA