Commissioning, operation – WIKA MHC-1 User Manual
Page 18

18
WIKA operating instructions pressure transmitter, model MHC-1
14035467.01 08/2012 GB/D/F/E
GB
6. Commissioning, operation
6.3 Configuration of the pressure transmitter
Factory settings
■
Bit rate = 250 kbit/s
■
CANopen: Node-ID = 1
■
J1939: Source address = 128
For further information on J1939 see "Additional instructions MHC-1 J1939“
The "Additional instructions" are available for download at www.wika.com.
6.4 EasyCom software installation
System requirement:
■
Operating system Microsoft
®
Windows
®
2000, XP, Vista or Windows
®
7
■
WIKA software EasyCom CANopen/J1939 (EasyCom CANopen/J1939 are available for download at
www.wika.com).
Windows is a registered trademark of Microsoft Corporation in the United States and other countries.
Installation
■
Connect the CAN adapter (PEAK PCAN-USB) to the PC and the pressure transmitter.
■
Install driver (once).
■
Start the CAN software (EasyCom CANopen/J1939).
■
Make sure that the correct bit rate and node ID / address of the pressure transmitter is used.
For further information on the CAN interface see "Additional instructions"
The “Additional instructions” are available for download at www.wika.com.