beautypg.com

Specifications – WIKA MHC-1 User Manual

Page 11

background image

11

WIKA operating instructions pressure transmitter, model MHC-1

14035467.01 08/2012 GB/D/F/E

GB

3. Specifications

Temperature error

The model MHC-1 is temperature compensated in the range from -40 ... +85 °C.

Temperature range 0 ... 60 °C:

≤ 0.5 % of span

Temperature range -20 ... +85 °C: ≤ 1 % of span

Temperature range -40 ... 0 °C:

≤ 1 % of span

Settling time

≤ 1.5 ms (Baud rate ≥ 125k)

Long-term stability

≤ ±0.2 % of span/year

3.6 Operating conditions

Ingress protection (per IEC 60529)

IP 6K9K

The stated ingress protection only applies when plugged in using a mating connector that has the

appropriate ingress protection.

Vibration resistance (per IEC 60068-2-6)

20 g

Shock resistance (per IEC 60068-2-27)

500 g

Service life

> 10 million load cycles