11 supplement, 1 technical data, 11 .1 technical data – WIKA DPT-10 User Manual
Page 71
11
Supplement
11
.1 Technical data
General data
Pressure type
Differential pressure
Measuring principle
Piezoresistive
Communication interface
I
²C bus
Materials and weights
Material 316L corresponds to stainless steel 1.4404 or 1.4435
Materials, wetted parts
-
Process fitting with lateral flanges
C
22.8, 316L, Alloy C276
-
Separating diaphragm
316L, Alloy C-276, Tantalum, Alloy C-276 gold-
rhodium coated
-
Seal
FKM (Viton), FKM cleaned from oil and grease,
FKM for oxygen application, PTFE, PTFE for
oxygen application, NBR, copper, copper for oxy-
gen application
-
Closing screws
316L
Internal transmission liquid
Synthetic oil, Halocarbon oil
8)
Materials, non-wetted parts
-
Electronics housing
Plastic PBT (polyester), Alu die-casting powder-
coated
-
External electronics housing
plastic PBT (Polyester)
-
Socket, wall mounting plate external
electronics housing
plastic PBT (Polyester)
-
Seal between housing socket and wall
mounting plate
TPE (fixed connected)
-
Seal ring, housing cover
Silicone
-
Inspection window in housing cover for
indicating and adjustment module
Polycarbonate (UL-746-C listed)
-
Screws and nuts for lateral flange
PN
160: hexagon screw ISO 4014-M12 x 90-A4,
PN
420: hexagon nut ISO 4032-M12-A4-bs
-
Ground terminal
316Ti/316L
-
Connection cable with version IP 68
(1 bar)
PE, PUR, FEP
-
Connection between IP 68 transmitter
and external electronics housing
PUR
-
Type plate support with IP 68 version on
cable
PE hard
8)
Halocarbon oil generally with oxygen applications, not with vacuum and
absolute pressure measuring range < 1 bar
abs
.
Differential pressure transmitter DPT10 - metal measuring diaphragm • Foundation Fieldbus
71
11 Supplement
37246
-
EN
-100120