beautypg.com

11 supplement, 1 technical data, 11 .1 technical data – WIKA DPT-10 User Manual

Page 71

background image

11

Supplement

11

.1 Technical data

General data

Pressure type

Differential pressure

Measuring principle

Piezoresistive

Communication interface

I

²C bus

Materials and weights

Material 316L corresponds to stainless steel 1.4404 or 1.4435

Materials, wetted parts

-

Process fitting with lateral flanges

C

22.8, 316L, Alloy C276

-

Separating diaphragm

316L, Alloy C-276, Tantalum, Alloy C-276 gold-
rhodium coated

-

Seal

FKM (Viton), FKM cleaned from oil and grease,
FKM for oxygen application, PTFE, PTFE for
oxygen application, NBR, copper, copper for oxy-
gen application

-

Closing screws

316L

Internal transmission liquid

Synthetic oil, Halocarbon oil

8)

Materials, non-wetted parts

-

Electronics housing

Plastic PBT (polyester), Alu die-casting powder-
coated

-

External electronics housing

plastic PBT (Polyester)

-

Socket, wall mounting plate external
electronics housing

plastic PBT (Polyester)

-

Seal between housing socket and wall
mounting plate

TPE (fixed connected)

-

Seal ring, housing cover

Silicone

-

Inspection window in housing cover for
indicating and adjustment module

Polycarbonate (UL-746-C listed)

-

Screws and nuts for lateral flange

PN

160: hexagon screw ISO 4014-M12 x 90-A4,

PN

420: hexagon nut ISO 4032-M12-A4-bs

-

Ground terminal

316Ti/316L

-

Connection cable with version IP 68
(1 bar)

PE, PUR, FEP

-

Connection between IP 68 transmitter
and external electronics housing

PUR

-

Type plate support with IP 68 version on
cable

PE hard

8)

Halocarbon oil generally with oxygen applications, not with vacuum and
absolute pressure measuring range < 1 bar

abs

.

Differential pressure transmitter DPT10 - metal measuring diaphragm • Foundation Fieldbus

71

11 Supplement

37246

-

EN

-100120