beautypg.com

Specifications – WIKA A-10 User Manual

Page 14

background image

14

WIKA operating instructions pressure transmitter model A-10

11218720.10 01/2012 GB/D/F/E

GB

3. Specifications

Designation

Ingress

protection

Wire

cross-section

Cable Ø Cable

material

Circular connector M12 x 1 (4-pin)

without mating connector

IP 67

-

-

-

straight with solid laid cable

IP 67

3 x 0.34 mm

2

4.4 mm

PUR

angled with solid laid cable

IP 67

3 x 0.34 mm

2

4.4 mm

PUR

Cable outlet

IP 67

3 x 0.34 mm

2

4 mm

PUR

unshielded

IP 67

3 x 0.34 mm

2

4 mm

PUR

OEM version, unshielded

IP 67

3 x 0.14 mm

2

2.85 mm

TPU

The stated ingress protection (per IEC 60529) only applies when plugged in using mating connectors that have the appropriate ingress

protection.

Short-circuit resistance

S

+

vs. 0V

Reverse polarity protection

U

B

vs. 0V

Insulation voltage

DC 500 V

3.8 Materials
Wetted parts

Stainless steel 316L

from 10 bar 316L and 13-8 PH

Non-wetted parts

Stainless steel 316L, HNBR, PA66

For sealing materials see "Process connections"