IQ SERIES T1 + DSX-1 NETWORK INTERFACE MODULE (NIM)

P/N 1202803L1

For more detailed documentation, visit us online at

www.adtran.com

Quick Start Guide, 61202803L1-13A, March 2004

Technical Support 1-888-4ADTRAN (1-888-423-8726)

Copyright

© 2004 ADTRAN, All Rights Reserved

S

PECIFICATIONS

Network Interface

Framing:

SF / ESF with auto detection

Line Coding:

AMI / B8ZS

Input signal:

to -36 dB

Clock Source:

network or internal

Line Build Out:

0, -7.5dB, -15 dB, -22.5dB

Data Rate:

56k or 64k

Connector:

RJ-48

DSX-1 Interface

Framing:

SF / ESF with auto detection

Line Coding:

AMI / B8ZS

Input signal:

0 to -7.5 dB

Data Rate:

56k or 64k synchronous

Line Build Out:

0 - 655 ft

Connector:

RJ-48

Compliance

FCC Part 15, Class A
FCC Part 68
Industry Canada CS03
UL and CUL

S

PECIFICATIONS

(

CONTINUED

)

Environmental

Operating Temperature:

0 to 50 C

Storage Temperature:

-40 to 85 C

Relative Humidity:

Up to 95% non-condensing

I

NSTALLATION

I

NSTRUCTIONS

1.

Remove the power from the unit.

2.

Slide the option module into the option slot until the module is firmly
seated against the front of the chassis.

3.

Secure the pins at both edges of the module.

4.

Connect the cables to the associated device(s).

5.

Complete installation of the Base Unit.

6.