beautypg.com

3 defining the rc-63d and rc-63dl, Defining the rc-63d and rc-63dl, Table 6: rc-63a/eu rear panel features – Kramer Electronics RC-63DL User Manual

Page 13: Table 6

background image

Installing the Room Controller

9

9

Table 6: RC-63A/EU Rear Panel Features

#

Feature

Function

1

GND Connection

Ground connection for the potentiometer

2

LVL (LEVEL) Connection

Wiper of potentiometer

3

+V PIN

+V connection for the potentiometer

4

FIRMWARE UPGRADE Switch For technical support use only

5

IR IN Receiver

Receives IR remote commands

6

K-NET TERM Switch

For line termination

7

RELAY Connections

Connect to room items (such as lighting, screen settings, blinds, and

so on)

8

IR Connections

Control a machine via an IR Emitter

9

RS-232 Connections

Connect to the RS-232 connector on the A/V equipment or a PC or other

Serial Controller

10

PROGRAM (USB) Connector Connect to a computer for unit configuration

11

K-NET Connections

On K-NET and K-NET LOOP, PIN GND is for the Ground connection

1

12

;

PIN B (-) and PIN A (+) are for RS-485, and PIN +12V is for powering the

unit

K-NET LOOP Connections

13

Grounding Screw

Connect to grounding wire (optional), see section

6.4

4.3 Defining the RC-63D and RC-63DL

The Kramer RC-63D is available as a 2 Gang wall plate for the USA or a 2 Gang

wall plate for Europe. It features 6 front panel buttons designed in two groups;

one group of 2 buttons, and another group of 4 buttons. Each group can be

programmed according to the user's requirements. The:

RC-63D has the DISPLAY and SOURCES labels printed on the unit

RC-63DL is the default room controller included as part of the

SummitView™ Standard Kit Box and the SummitView™ Essentials Kit Box

and described in that user manual, and has an LCD label, letting you program

the required group label, as well as rolling text on the display

The RC-63D also includes:

A configurable digital volume control adjustment knob with five LEDs

Two relays for the simplified and centralized control of room functions (such

as lighting, closing blinds, screen settings, and so on)

An IR output, a bidirectional RS-232 port, and two K-NET ports

An IR-learner for the customized control of external sources, memorizing the

IR commands from different remote transmitters

A USB port is included for programming the RC-63D via a computer.

Figure 5

,

Figure 6

,

Table 7

and

Table 8

define the RC-63D and RC-63DL.

1 The ground connection is sometimes connected to the shield of the RS-485 cable (in most applications, it is not connected)

This manual is related to the following products: