6 technical specifications, 1 default communication parameters, 2 toggling between protocols – Kramer Electronics VS-21HDCP-IR User Manual
Page 13: Technical specifications, Default communication parameters, 6technical specifications

10
VS-21HDCP-IR - Technical Specifications
6
Technical Specifications
INPUTS:
2 DVI-D on DVI-I connectors, 1.2Vpp; DDC signal 5Vpp
(TTL)
OUTPUT:
1 DVI-D on a DVI-I connector; DDC signal 5Vpp (TTL)
BANDWIDTH:
6.75Gbps (2.25Gbps per graphic channel)
POWER CONSUMPTION:
5V DC, 250mA
OPERATING TEMPERATURE:
0° to +40°C (32° to 104°F)
STORAGE TEMPERATURE:
-40° to +70°C (-40° to 158°F)
HUMIDITY:
10% to 90%, RHL non-condensing
DIMENSIONS:
14.3cm x 12.2cm x 4.36cm (5.63" x 4.8" x 1.72", W, D, H)
WEIGHT:
0.3kg (0.67lbs) approx.
ACCESSORIES:
Power supply, infrared remote controller, bracket
installation kit
Specifications are subject to change without notice
6.1
Default Communication Parameters
RS-232
Protocol 2000
Protocol 3000 (Default)
Baud Rate
9600
Baud Rate
115,200
Data Bits
8
Data Bits
8
Stop Bits
1
Stop Bits
1
Parity
None
Parity
None
Command Format
HEX
Command Format
ASCII
Example (Output 1
to Input 1)
0x01, 0x81, 0x81,
0x81
Example (Output 1 to
Input 1)
#AV 1>1
6.2
Toggling Between Protocols
To set the machine to Protocol 3000, do the following:
1. Disconnect the power.
2. Press and hold the SELECT button while connecting the power.
The red IR LED flashes.
3. Release the SELECT button.
Use this method to switch between Protocol 3000 and Protocol 2000.