beautypg.com

6 technical specifications, 1 default communication parameters, 2 toggling between protocols – Kramer Electronics VS-21HDCP-IR User Manual

Page 13: Technical specifications, Default communication parameters, 6technical specifications

background image

10

VS-21HDCP-IR - Technical Specifications

6

Technical Specifications

INPUTS:

2 DVI-D on DVI-I connectors, 1.2Vpp; DDC signal 5Vpp
(TTL)

OUTPUT:

1 DVI-D on a DVI-I connector; DDC signal 5Vpp (TTL)

BANDWIDTH:

6.75Gbps (2.25Gbps per graphic channel)

POWER CONSUMPTION:

5V DC, 250mA

OPERATING TEMPERATURE:

0° to +40°C (32° to 104°F)

STORAGE TEMPERATURE:

-40° to +70°C (-40° to 158°F)

HUMIDITY:

10% to 90%, RHL non-condensing

DIMENSIONS:

14.3cm x 12.2cm x 4.36cm (5.63" x 4.8" x 1.72", W, D, H)

WEIGHT:

0.3kg (0.67lbs) approx.

ACCESSORIES:

Power supply, infrared remote controller, bracket
installation kit

Specifications are subject to change without notice at

http://www.kramerelectronics.com

6.1

Default Communication Parameters

RS-232

Protocol 2000

Protocol 3000 (Default)

Baud Rate

9600

Baud Rate

115,200

Data Bits

8

Data Bits

8

Stop Bits

1

Stop Bits

1

Parity

None

Parity

None

Command Format

HEX

Command Format

ASCII

Example (Output 1
to Input 1)

0x01, 0x81, 0x81,
0x81

Example (Output 1 to
Input 1)

#AV 1>1

6.2

Toggling Between Protocols

To set the machine to Protocol 3000, do the following:

1. Disconnect the power.

2. Press and hold the SELECT button while connecting the power.

The red IR LED flashes.

3. Release the SELECT button.

Use this method to switch between Protocol 3000 and Protocol 2000.