beautypg.com

Kramer Electronics VP-411DS User Manual

Page 16

background image

KRAMER: SIMPLE CREATIVE TECHNOLOGY

Flash Memory Upgrade

14

2. Under the “Step 1 – Communications” area, set the definitions on the screen as follows:

 COM Port: select the active COM port on your computer
 Baud Rate: 19200
 Device: LPC2368
 Interface: None (ISP)
 Oscillator Freq. (MHz): 12.000

3. Under the “Step 2 – Erase” area, check the “Erase all Flash+Code Rd Prot” box.

4. Under the “Step 3 – Hex File” area select the hex file. For example, select

VP-411DS_12.hex”.

5. Under the “Step 4 – Options” area, check the “Verify after programming” box.

6. In order to verify communication, select "Read device signature" from the ISP menu.

You should get a response as the example below:

7. Under the “Step 5 – Start!” area, press the start button and wait for the completion of the

process.

8. Close the “Flash Magic” window.

9. Turn the power OFF on the VP-411DS unit.

10. Disconnect the RS-232 rear panel port on the VP-411DS unit from the Null-modem

adapter.

11. On the underside panel, slide the switch to NORMAL.

12. Turn the power ON on the VP-411DS unit.