6 care and maintenance, 7 dismantling and repairs, 8 eliminating faults – Festo Привод со шпинделем и трапециевидной резьбой DMES User Manual
Page 13: 6care and maintenance, 7dismantling and repairs, 8eliminating faults

DG..−...−GA, FDG−...−GA, DMES−...−GA
Festo DG..−...−GA, FDG−...−GA, DMES−...−GA 0503a English
13
6
Care and maintenance
S
Lubricate the roller bearing cassettes of
the slide at intervals as specified in the
operating instructions for the linear axis.
Access to the lubricating nipple
aA:
S
Remove the cover profile as described in
the chapter Fitting".
S
Clean the DG..−/FDG−/DMES−...
−GA only
with water (max. 60 °C).
7
Dismantling and repairs
Replacing heavily worn parts:
S
Order a wearing parts kit for the protected guide.
8
Eliminating faults
Fault
Cause
Remedy
Brushes visibly worn
Lon operatin period
Order a wearin parts kit
Sliding elements worn
Long operating period
Order a wearing parts kit
Grinding noises
Cover profile deformed
Replace cover profile
Fig. 10
aA