Installation

1.

Identify the connectors on the Transmitter (LC Fiber out) and Receiver (LC FIBER in)
as indicated on the product labels.

2. Verify that the distance between the Transmitter and Receiver is within MuxLab

specifications (see Specifications table).

3. To install the Transmitter:

3a. Connect the Transmitter to the SDI video source with a BNC 75-ohm coaxial

cable.

3b. Remove the white protective plug from the fiber connector. Connect one

multimode or singlemode optical fiber cable with LC connector. Keep the plug
and put it back if the fiber is not present.

3c. DO NOT LOOK into the fiber or module when the power is on.
3d. Connect the external power supply or the Hirose power cable if being powered by

an SDI camcorder that supports the Hirose interface. The power cable has a
locking mechanism, push the plug and rotate it until it locks.

4. To install the Receiver:

4a. Connect the Receiver to the SDI display equipment with a BNC 75 ohm compliant

cable.

4b. Remove the white protective plug from the fiber connector. Keep the plug and put

it back if the fiber is not present. Connect the other side of the fiber.

4c. Connect the external power supply.
4d. Power-up the equipment and verify the image quality. Verify that both power

LEDs are on. With a valid source check the transmitter side that the signal
LED is on, and on the receiver side that the signal LED is on.

Troubleshooting

The following table describes some of the symptoms, probable causes and possible solutions
in respect to the installation of the HD-SDI Extender Kit:

LEDS

Status

Possible cause

Action

On both
unit:

Power

OFF

No AC power or
defective power supply.

Try swapping the two power
supplies.

On TX:

Signal

OFF

No source signal or
incompatible signal.

Check source signal.

Check coax cable. It must be 75
ohm and length must be less than
330 ft (100m).

On RX:

Signal

OFF

No source signal or
incompatible signal.

Fiber not connected or
broken.

Remote unit off or
defective.

Check source signal.

Check fiber cable.

Check distance specs for fiber
cable (see specifications table).

On both
unit:

Power

&

Signal

ON but no
signal on
monitor

Display monitor not
working.

Coax cable not
connected or broken.

Try with another monitor.

Check coax cable. It must be 75
ohm and length must be less than
330 ft (100m). Some equipment
may not accepted up to 330ft
(100m).

If you still cannot diagnose the problem, please call MuxLab Customer Technical Support at