R164 Controller Manual

09/15/2005

Encoder Usage


The R164 can also be used as reference to home by connecting to an US Digital E2

Encoder. The pinouts are as follows:

Pin Number Function
1 Ground
2

Index

3 Channel

A

4

+ 5 VDC

5 Channel

B


The E2 encoder requires a separate +5 Volt power supply, as the R164 controller

cannot provide a strong enough source of power.

In order to use the Indexer as a reference to home, connect Pin 2 from the encoder
to one of the inputs on the controller. From the controller’s side, for best results use

Pin 5, the switch closure to ground.

In addition, use a pull-down resistor (10k Ω) to ensure that the controller will
recognize the difference between high and low (4.85V and 0.5V).

Figure 8: Encoder Pin Connection Schematic


After successfully connecting the encoder to the controller, now you can program the

controller to run continuously. The motor will stop movement when the indexer goes
high. This will send the high signal to Pin 5 on the controller.


If using channel 1, use this command to start the homing routine:

/1P0R