9
Parameter
Number
Register
Number
Description
Range
Scaling
Type
P2‐18
218
User relay 2 output function select
0: Drive running
1: Drive healthy
2: Motor at target speed
3: Motor Speed > 0
4: Motor Speed > limit
5: Motor Current > limit
6: Motor Torque > limit
7: 2
nd
Analog input > limit
U16
P2‐19
219
User relay 2 upper limit
P2‐20 to 2000
1 = 0.1%
U16
P2‐20
220
User relay 2 lower limit
0 to P2‐19
1 = 0.1%
U16
P2‐21
221
Display scaling factor
0 to 30000
1 = 0.001
U16
P2‐22
222
Display scaling source
0: Motor Speed
1: Motor Current
2: 2
nd
Analog input
U16
P2‐23
223
Zero Speed holding time
0 to 600
1 = 0.1
U16
P2‐24
224
Effective switching frequency
0 = 4kHz
1 = 8kHz
2 = 12kHz
3 = 16kHz
4 = 24kHz
5 = 32kHz
U16
P2‐25
225
Fast deceleration ramp time
0 to 3000
S2…S3 1 = 0.01s
S4…S7 1 = 0.1s
U16
P2‐26
226
Spin start enable
0 : Disabled
1 : Enabled
1
WORD
P2‐27
227
Standby mode
0 to 25000
1 = 0.01
U16
P2‐28
228
Slave speed scaling control
0: Disabled
1: Preset by slave speed scaling
2: P2‐33 scaling + analog in1 offset
3: P2‐33 scaling + analog in1 scaling
U16
P2‐29
229
Slave Speed scaling factor
‐5000 to 5000
1 = 0.1
S16
P2‐30
230
Analog input 1 format
0 = 0‐10V
1 = ‐10‐10V
2 = 0‐20mA
3 = t 4‐20mA
4 = r 4‐20mA
5 = t 20‐4mA
6 = r 20‐4mA
U16
P2‐31
231
Analog input 1 scaling
0 to 5000
1 = 0.1
U16
P2‐32
232
Analog input 1 offset
‐5000 to 5000
1 = 0.1
S16
P2‐33
233
Analog input 2 format
0 = 0‐10V
1 = Ptc‐th
2 = 0‐20mA
3 = t 4‐20mA
4 = r 4‐20mA
5 = t 20‐4mA
6 = r 20‐4mA
U16
P2‐34
234
Analog input 2 scaling
0 to 5000
1 = 0.1
U16
P2‐35
235
Analog input 2 offset
‐5000 to 5000
1 = 0.1
S16
P2‐36
236
Start mode select
0 = Edge‐r
1 = Auto‐0
2 = Auto‐1
3 = Auto‐2
4 = Auto‐3
5 = Auto‐4
6 = Auto‐5
U16
P2‐37
237
Keypad restart speed
0: Minimum speed
1: Previous keypad speed
2: Current running Speed
3: Preset Speed 8
U16
P2‐38
238
Mains loss stop control
0: Mains loss ride through
1: Coast to Stop
2: Fast ramp to stop
U16
P2‐39
239
Parameter Lock
0: Unlocked
1: Locked
WORD
P2‐40
240
Extended parameter access code definition
0 ... 9 999
U16